FC Fibre Pigtails Price in Kenya
SC/APC Single Mode Fibre Pigtail in Kenya
KSh 200.00
1 available
Continue shoppingSC/APC Single Mode Fibre Pigtail in Kenya
The SC/APC Single Mode Fibre Pigtail is a factory-terminated optical fibre lead designed for professional fibre termination by fusion splicing. It features a green SC/APC connector on one end and an unterminated fibre end on the other, allowing technicians to splice it directly onto incoming single-mode fibre inside an ODF, fibre distribution box, splice tray, patch panel or fibre termination enclosure.
Modern SC/APC pigtails commonly use single-mode OS2 fibre, with G.652.D and bend-insensitive G.657.A1 variants widely available. CommScope currently lists single-fibre SC/APC pigtails using G.652.D and G.657.A1 single-mode fibre with yellow construction, confirming this configuration for professional fibre installations. Corning also lists SC/APC simplex single-mode OS2 pigtails within its fibre pigtail portfolio.
At Fiber Optics Kenya, the SC/APC Single Mode Fibre Pigtail is suitable for FTTH, GPON, telecommunications, ISP infrastructure, ODFs, fibre distribution boxes, CATV networks and other single-mode fibre termination projects. Customers can also source compatible SC/APC adapters, splice sleeves, ODFs, FDBs, PLC splitters, patch cords, fibre trays and optical testing equipment.
Key Product Specifications
| Specification | Details |
|---|---|
| Product Name | SC/APC Single Mode Fibre Pigtail |
| Product Type | Fibre Optic Pigtail |
| Connector Type | SC/APC |
| Connector Polish | APC |
| Typical Connector Colour | Green |
| Fibre Mode | Single Mode |
| Typical Fibre Category | OS2 |
| Typical Fibre Size | 9/125 µm |
| Common Fibre Types | G.652.D / G.657.A1 / G.657.A2 depending on model |
| Configuration | Simplex |
| Fibre Count | 1 |
| Connectorized Ends | 1 |
| Opposite End | Unterminated / Bare Fibre |
| Typical Buffer Diameter | 0.9 mm / 900 µm |
| Typical Buffer Colour | Yellow |
| Common Lengths | 1 m / 1.5 m / 2 m / 3 m |
| Common Wavelengths | 1310 nm / 1490 nm / 1550 nm |
| Typical Installation | Fusion splicing |
| Applications | FTTH, PON, ODF, FDB, telecom, ISP |
| Professional Installation | Available |
| Delivery | Available throughout Kenya |
CommScope's current fibre-pigtail portfolio includes single-fibre, yellow, single-mode SC/APC products using G.652.D and G.657.A1 fibre.
What Is an SC/APC Fibre Pigtail?

An SC/APC fibre pigtail has a connector on only one end.
| Feature | SC/APC Fibre Pigtail |
|---|---|
| Connectorized End | SC/APC |
| Other End | Bare fibre |
| Number of Fibres | 1 typically |
| Fibre Mode | Single Mode |
| Typical Fibre Category | OS2 |
| Primary Purpose | Fibre termination |
| Installation Method | Fusion splicing |
| Typical Location | ODF, FDB, splice tray, fibre box |
The bare end is normally fusion-spliced onto the installed fibre while the SC/APC connector plugs into an SC/APC adapter.
What Does SC/APC Single Mode Mean?

| Term | Meaning |
|---|---|
| SC | Standard / Subscriber Connector |
| APC | Angled Physical Contact |
| SC/APC | SC connector with angled polished ferrule |
| Single Mode | Fibre optimized for long-distance optical transmission |
| OS2 | Single-mode fibre category |
| 9/125 | Approx. 9 µm core and 125 µm cladding |
| Pigtail | Connector at one end and bare fibre at the other |
| Simplex | One optical fibre |
SC/APC Connector Features
| Feature | Description |
|---|---|
| Connector Type | SC |
| Polish Type | APC |
| Typical Colour | Green |
| Ferrule Diameter | Approx. 2.5 mm |
| Ferrule Material | Ceramic commonly |
| End-Face Angle | Approx. 8° commonly |
| Connection Method | Push-Pull |
| Fibre Mode | Single Mode |
| FTTH Compatibility | Excellent |
| PON Compatibility | Excellent |
| CATV Compatibility | Excellent |
SC/APC's angled end face helps reduce reflected optical power, which is one reason APC interfaces are common in PON, FTTH and CATV networks.
9/125 Single Mode Fibre Explained
| Fibre Component | Typical Diameter |
|---|---|
| Optical Core | Approx. 9 µm |
| Cladding | 125 µm |
| Tight Buffer | 900 µm / 0.9 mm commonly |
The small core supports single-mode optical propagation and makes the fibre suitable for long-distance communications.
OS2 Single Mode Fibre Characteristics
| Characteristic | Typical Description |
|---|---|
| Fibre Category | OS2 |
| Fibre Mode | Single Mode |
| Typical Size | 9/125 µm |
| Typical Colour | Yellow |
| Common Wavelengths | 1310 / 1550 nm |
| Optical Attenuation | Low |
| Long-Distance Performance | Excellent |
| FTTH Networks | Excellent |
| Telecommunications | Excellent |
| ISP Infrastructure | Excellent |
| Enterprise Networks | Excellent |
Corning currently lists SC APC to pigtail assemblies using single-mode OS2 fibre, including carrier-network products.
G.652D vs G.657A1 vs G.657A2
| Feature | G.652D | G.657A1 | G.657A2 |
|---|---|---|---|
| Fibre Mode | Single Mode | Single Mode | Single Mode |
| Long-Distance Performance | Excellent | Excellent | Excellent |
| Bend Performance | Standard | Improved | Enhanced |
| FTTH Use | Good | Excellent | Excellent |
| ODF Installation | Excellent | Excellent | Excellent |
| Compact Fibre Boxes | Good | Better | Excellent |
| Indoor Fibre Routing | Excellent | Excellent | Excellent |
CommScope specifically lists G.652.D and G.657.A1 fibre in current SC/APC single-mode pigtail configurations.
Typical Optical Performance
| Optical Parameter | Typical / Representative Description |
|---|---|
| Fibre Mode | Single Mode |
| Fibre Category | OS2 |
| Typical Fibre Size | 9/125 µm |
| Connector Type | SC/APC |
| Operating Wavelengths | 1310 / 1490 / 1550 nm |
| Insertion Loss | Typically low, product dependent |
| Return Loss | Very high with APC polish |
| Back Reflection | Very low |
| Long-Distance Compatibility | Excellent |
| PON Compatibility | Excellent |
Exact insertion and return-loss values should be confirmed from the specific supplied manufacturer's datasheet.
Typical Mechanical Characteristics
| Parameter | Typical Description |
|---|---|
| Configuration | Simplex |
| Fibre Count | 1 |
| Connector | SC/APC |
| Connector Colour | Green |
| Fibre Colour | Yellow |
| Typical Buffer Diameter | 0.9 mm |
| Typical Fibre Category | OS2 |
| Cable Construction | Tight Buffered / unjacketed depending on model |
| Jacket Rating | LSZH / Riser depending on model |
| Ferrule Material | Ceramic |
| Installation Method | Fusion Splicing |
CommScope lists SC/APC pigtails with yellow construction and dual-rated LSZH/Riser options, while Corning offers 900 µm single-mode pigtail configurations.
SC/APC vs SC/UPC Fibre Pigtail
| Feature | SC/APC | SC/UPC |
|---|---|---|
| Connector Colour | Green | Blue |
| Polish Type | Angled Physical Contact | Ultra Physical Contact |
| Back Reflection | Lower | Higher |
| FTTH / PON | Very Common | Used |
| CATV | Excellent | Less preferred |
| Enterprise LAN | Application dependent | Very Common |
| Direct APC-to-UPC Mating | No | No |
Always match APC connectors with APC interfaces and UPC connectors with UPC interfaces.
Fibre Pigtail vs Fibre Patch Cord
| Feature | Fibre Pigtail | Fibre Patch Cord |
|---|---|---|
| Connectorized Ends | 1 | 2 |
| Bare Fibre End | Yes | No |
| Requires Splicing | Yes | No |
| Primary Purpose | Fibre termination | Equipment interconnection |
| ODF Installation | Excellent | Used after termination |
| FDB Installation | Excellent | Application dependent |
| Factory-Polished Connector | One end | Both ends |
| Typical Length | Short | Wide range |
Why Use an SC/APC Pigtail?
Factory-Polished Connector
The SC/APC connector is polished under controlled manufacturing conditions before installation.
Low Back Reflection
The APC angled polish helps reduce reflected optical signals.
Professional Fusion-Splice Termination
The bare end can be fusion-spliced to installed single-mode fibre to create a reliable permanent termination.
OS2 Single Mode Performance
Single-mode OS2 fibre provides excellent low-loss performance for telecommunications and access networks.
Bend-Insensitive Fibre Options
G.657A1 and similar fibres make routing easier inside compact fibre boxes and trays.
Easy Identification
The green connector immediately distinguishes SC/APC from blue SC/UPC.
Simplex Construction
One pigtail can terminate each individual core of a multi-core fibre cable.
Watch SC/APC Single Mode Fibre Pigtail
Watch on YouTube: https://youtu.be/pXkRAniethg
The SC/APC Single Mode Fibre Pigtail provides a professional method of creating SC/APC connectorized termination points from bare single-mode fibre. The pigtail normally consists of one yellow fibre with a green SC/APC connector at one end and an unterminated fibre tail at the other. Current CommScope products confirm this arrangement using single-mode G.652.D and G.657.A1 fibre.
The APC connector is particularly useful in optical networks where reflected light needs to be minimized. This makes the pigtail highly suitable for FTTH, PON, CATV, fibre distribution and telecommunications networks. The pigtail can be fusion-spliced to the installed fibre and organized inside an ODF, splice tray or distribution enclosure while the connector remains accessible at the adapter panel.
Using a factory-terminated pigtail also simplifies professional fibre installations because technicians only need to prepare and splice the bare end. Fiber Optics Kenya can supply SC/APC pigtails alongside SC/APC adapters, splice protection sleeves, ODFs, FDB boxes, PLC splitters, fibre splice trays, SC/APC patch cords and fibre testing equipment, making it easier to source a complete termination solution.
Applications of SC/APC Single Mode Fibre Pigtail
1. FTTH Networks
Terminate subscriber or distribution fibre where SC/APC connectivity is required.
2. GPON Networks
Ideal for passive optical network installations using APC connector interfaces.
3. Optical Distribution Frames
Fusion-splice incoming fibre to the pigtail and mount the SC/APC connector in an adapter.
4. Fibre Distribution Boxes
Create organized SC/APC termination points inside FDBs.
5. PLC Splitter Installations
Connect fibre infrastructure to SC/APC-terminated PON splitters.
6. Telecommunications Networks
Provide permanent single-mode fibre termination in telecom installations.
7. ISP Infrastructure
Use in distribution cabinets, ODFs and access-network enclosures.
8. CATV Networks
APC polishing is particularly useful where low return reflection is important.
9. Fibre Joint Closures
Provide connectorized termination where the network design requires it.
10. Fibre Testing and Maintenance
Create standardized SC/APC interfaces for compatible test equipment.
Typical ODF Termination Process
| Step | Installation Process |
|---|---|
| 1 | Route fibre cable into ODF |
| 2 | Remove outer cable sheath |
| 3 | Separate the fibre to be terminated |
| 4 | Prepare SC/APC pigtail bare end |
| 5 | Strip and clean both fibres |
| 6 | Precision-cleave fibre ends |
| 7 | Fusion-splice fibres together |
| 8 | Install splice protection sleeve |
| 9 | Place splice inside tray |
| 10 | Route pigtail neatly |
| 11 | Insert SC/APC connector into adapter |
| 12 | Test optical loss |
SC/APC Pigtail vs Fast Connector
| Feature | SC/APC Pigtail + Fusion Splice | SC/APC Fast Connector |
|---|---|---|
| Connector Polish | Factory polished | Factory-prepared internal interface |
| Joint Type | Fusion splice | Mechanical field termination |
| Consistency | Excellent when properly installed | Installer dependent |
| Fusion Splicer Required | Yes | No |
| Installation Speed | Moderate | Faster |
| ODF Installation | Excellent | Good |
| Permanent Fibre Infrastructure | Excellent | Good |
| Large Professional Projects | Common | Useful for rapid deployment |
Recommended Accessories
| Accessory | Purpose |
|---|---|
| SC/APC Adapter | Couples compatible SC/APC connectors |
| Fusion Splice Sleeve | Protects completed splice |
| Fibre Splice Tray | Organizes fibres and splices |
| Optical Distribution Frame | Structured fibre termination |
| Fibre Distribution Box | Protects fibre termination points |
| PLC Splitter | Splits PON optical signals |
| SC/APC Patch Cord | Connects terminated fibre to equipment |
| Fibre Stripper | Removes fibre coating |
| Precision Fibre Cleaver | Prepares fibre for fusion |
| Fusion Splicer | Creates permanent optical splice |
| Optical Power Meter | Measures fibre signal level |
| PON Power Meter | Tests PON signals |
| Visual Fault Locator | Assists fibre fault tracing |
| OTDR | Tests fibre link performance |
| SC/APC Connector Cleaner | Cleans connector end faces |
Why Buy SC/APC Single Mode Fibre Pigtail from Fiber Optics Kenya?

| Why Choose Fiber Optics Kenya? | Customer Benefit |
|---|---|
| SC/APC Pigtail Options | Suitable for professional fibre termination |
| Single Mode OS2 Options | Excellent optical performance |
| G.657 Fibre Options | Improved bend performance |
| Multiple Lengths | Match different enclosure sizes |
| SC/APC Adapters | Compatible termination accessories |
| ODFs & FDBs | Complete fibre-distribution systems |
| PLC Splitters | PON network components available |
| Splicing Accessories | Complete installation solution |
| Testing Equipment | Support commissioning and maintenance |
| Technical Guidance | Help choosing compatible components |
| Bulk Supply | Suitable for ISPs and contractors |
| Nationwide Delivery | Supply throughout Kenya |
Frequently Asked Questions
What is an SC/APC Single Mode Fibre Pigtail?
It is a single-mode fibre lead with an SC/APC connector on one end and bare fibre on the other, designed mainly for splicing and fibre termination.
What colour is an SC/APC connector?
SC/APC connectors are normally green.
What colour is single-mode pigtail fibre?
Single-mode pigtails are commonly yellow.
Is SC/APC single mode?
Yes. CommScope currently lists SC/APC single-mode fibre pigtails using G.652.D and G.657.A1 fibre.
What fibre size is normally used?
Typical single-mode pigtails use approximately 9/125 µm fibre.
What does APC mean?
APC means Angled Physical Contact.
Why is APC used?
The angled connector end face reduces optical back reflection, making APC useful in networks such as PON and CATV.
What is the difference between SC/APC and SC/UPC?
SC/APC uses an angled end face and is normally green, while SC/UPC uses an Ultra Physical Contact polish and is usually blue.
Can SC/APC connect directly to SC/UPC?
No. Their connector geometries differ and they should not be directly mated.
What is G.652D fibre?
G.652D is a widely used conventional single-mode fibre standard suitable for telecommunications and long-distance optical networks.
What is G.657A1 fibre?
G.657A1 is a bend-insensitive single-mode fibre designed to provide improved performance around tighter bends. CommScope lists G.657.A1 among its current SC/APC pigtail fibre types.
Is SC/APC suitable for FTTH?
Yes. SC/APC is widely suitable for FTTH and passive optical network termination.
Is it suitable for GPON?
Yes. SC/APC is commonly used in GPON installations.
Can it be installed in an ODF?
Yes. ODF termination is one of the main applications of a fibre pigtail.
Does it require fusion splicing?
Normally yes. The unterminated end is fusion-spliced to the installed fibre.
Can it be used in an FDB?
Yes. It is suitable for fibre distribution boxes requiring SC/APC outputs.
What is the difference between a pigtail and a patch cord?
A pigtail has one connector and one bare fibre end, while a patch cord has connectors on both ends.
Do you supply SC/APC adapters?
Yes. Fiber Optics Kenya can supply matching SC/APC adapters and termination accessories.
Do you supply PLC splitters?
Yes. Compatible PLC splitters and PON accessories can be supplied.
Do you supply ODFs and fibre boxes?
Yes. Compatible ODFs, FDBs, splice trays and fibre enclosures can be supplied.
Do you provide fibre splicing and testing?
Yes. Professional fibre fusion splicing, termination and testing support is available.
Do you deliver outside Nairobi?
Yes. Fiber Optics Kenya supplies fibre optic products and accessories throughout Kenya.
Contact Fiber Optics Kenya
Fiber Optics Kenya
Lyric House
7th Floor, Room S9
Kimathi Street
Nairobi
Phone: +254 704 991 492
Email: info@fibreopticskenya.co.ke
The SC/APC Single Mode Fibre Pigtail provides a reliable, low-reflection solution for fusion-splice termination in FTTH, PON, ODF and telecommunications networks.
Contact Fiber Optics Kenya for competitive pricing, SC/APC accessories, ODFs, fibre termination products, bulk orders and nationwide delivery across Kenya.