SC/APC Single Mode Fibre Pigtail in Kenya

FC Fibre Pigtails Price in Kenya

SC/APC Single Mode Fibre Pigtail in Kenya

KSh 200.00

1 available

Continue shopping

SC/APC Single Mode Fibre Pigtail in Kenya

Sc/APC PVC2.0 Fiber Pigtail, Single Mode 9/125 Fiber Green Adapter ...

The SC/APC Single Mode Fibre Pigtail is a factory-terminated optical fibre lead designed for professional fibre termination by fusion splicing. It features a green SC/APC connector on one end and an unterminated fibre end on the other, allowing technicians to splice it directly onto incoming single-mode fibre inside an ODF, fibre distribution box, splice tray, patch panel or fibre termination enclosure.

Modern SC/APC pigtails commonly use single-mode OS2 fibre, with G.652.D and bend-insensitive G.657.A1 variants widely available. CommScope currently lists single-fibre SC/APC pigtails using G.652.D and G.657.A1 single-mode fibre with yellow construction, confirming this configuration for professional fibre installations.  Corning also lists SC/APC simplex single-mode OS2 pigtails within its fibre pigtail portfolio. 

At Fiber Optics Kenya, the SC/APC Single Mode Fibre Pigtail is suitable for FTTH, GPON, telecommunications, ISP infrastructure, ODFs, fibre distribution boxes, CATV networks and other single-mode fibre termination projects. Customers can also source compatible SC/APC adapters, splice sleeves, ODFs, FDBs, PLC splitters, patch cords, fibre trays and optical testing equipment.

Key Product Specifications

SpecificationDetails
Product NameSC/APC Single Mode Fibre Pigtail
Product TypeFibre Optic Pigtail
Connector TypeSC/APC
Connector PolishAPC
Typical Connector ColourGreen
Fibre ModeSingle Mode
Typical Fibre CategoryOS2
Typical Fibre Size9/125 µm
Common Fibre TypesG.652.D / G.657.A1 / G.657.A2 depending on model
ConfigurationSimplex
Fibre Count1
Connectorized Ends1
Opposite EndUnterminated / Bare Fibre
Typical Buffer Diameter0.9 mm / 900 µm
Typical Buffer ColourYellow
Common Lengths1 m / 1.5 m / 2 m / 3 m
Common Wavelengths1310 nm / 1490 nm / 1550 nm
Typical InstallationFusion splicing
ApplicationsFTTH, PON, ODF, FDB, telecom, ISP
Professional InstallationAvailable
DeliveryAvailable throughout Kenya

CommScope's current fibre-pigtail portfolio includes single-fibre, yellow, single-mode SC/APC products using G.652.D and G.657.A1 fibre

What Is an SC/APC Fibre Pigtail?

Single Mode pigtails SC/APC - 1.5 meters | Tronik Gadgets Store

An SC/APC fibre pigtail has a connector on only one end.

FeatureSC/APC Fibre Pigtail
Connectorized EndSC/APC
Other EndBare fibre
Number of Fibres1 typically
Fibre ModeSingle Mode
Typical Fibre CategoryOS2
Primary PurposeFibre termination
Installation MethodFusion splicing
Typical LocationODF, FDB, splice tray, fibre box

The bare end is normally fusion-spliced onto the installed fibre while the SC/APC connector plugs into an SC/APC adapter.

What Does SC/APC Single Mode Mean?

Qoltec Pigtail fiber optic SC/APC | Singlemode | 9/125 | G657A | 1m (54129)  | Fiber optics networks | Qoltec
TermMeaning
SCStandard / Subscriber Connector
APCAngled Physical Contact
SC/APCSC connector with angled polished ferrule
Single ModeFibre optimized for long-distance optical transmission
OS2Single-mode fibre category
9/125Approx. 9 µm core and 125 µm cladding
PigtailConnector at one end and bare fibre at the other
SimplexOne optical fibre

SC/APC Connector Features

FeatureDescription
Connector TypeSC
Polish TypeAPC
Typical ColourGreen
Ferrule DiameterApprox. 2.5 mm
Ferrule MaterialCeramic commonly
End-Face AngleApprox. 8° commonly
Connection MethodPush-Pull
Fibre ModeSingle Mode
FTTH CompatibilityExcellent
PON CompatibilityExcellent
CATV CompatibilityExcellent

SC/APC's angled end face helps reduce reflected optical power, which is one reason APC interfaces are common in PON, FTTH and CATV networks.

9/125 Single Mode Fibre Explained

Fibre ComponentTypical Diameter
Optical CoreApprox. 9 µm
Cladding125 µm
Tight Buffer900 µm / 0.9 mm commonly

The small core supports single-mode optical propagation and makes the fibre suitable for long-distance communications.

OS2 Single Mode Fibre Characteristics

CharacteristicTypical Description
Fibre CategoryOS2
Fibre ModeSingle Mode
Typical Size9/125 µm
Typical ColourYellow
Common Wavelengths1310 / 1550 nm
Optical AttenuationLow
Long-Distance PerformanceExcellent
FTTH NetworksExcellent
TelecommunicationsExcellent
ISP InfrastructureExcellent
Enterprise NetworksExcellent

Corning currently lists SC APC to pigtail assemblies using single-mode OS2 fibre, including carrier-network products. 

G.652D vs G.657A1 vs G.657A2

FeatureG.652DG.657A1G.657A2
Fibre ModeSingle ModeSingle ModeSingle Mode
Long-Distance PerformanceExcellentExcellentExcellent
Bend PerformanceStandardImprovedEnhanced
FTTH UseGoodExcellentExcellent
ODF InstallationExcellentExcellentExcellent
Compact Fibre BoxesGoodBetterExcellent
Indoor Fibre RoutingExcellentExcellentExcellent

CommScope specifically lists G.652.D and G.657.A1 fibre in current SC/APC single-mode pigtail configurations. 

Typical Optical Performance

Optical ParameterTypical / Representative Description
Fibre ModeSingle Mode
Fibre CategoryOS2
Typical Fibre Size9/125 µm
Connector TypeSC/APC
Operating Wavelengths1310 / 1490 / 1550 nm
Insertion LossTypically low, product dependent
Return LossVery high with APC polish
Back ReflectionVery low
Long-Distance CompatibilityExcellent
PON CompatibilityExcellent

Exact insertion and return-loss values should be confirmed from the specific supplied manufacturer's datasheet.

Typical Mechanical Characteristics

ParameterTypical Description
ConfigurationSimplex
Fibre Count1
ConnectorSC/APC
Connector ColourGreen
Fibre ColourYellow
Typical Buffer Diameter0.9 mm
Typical Fibre CategoryOS2
Cable ConstructionTight Buffered / unjacketed depending on model
Jacket RatingLSZH / Riser depending on model
Ferrule MaterialCeramic
Installation MethodFusion Splicing

CommScope lists SC/APC pigtails with yellow construction and dual-rated LSZH/Riser options, while Corning offers 900 µm single-mode pigtail configurations. 

SC/APC vs SC/UPC Fibre Pigtail

FeatureSC/APCSC/UPC
Connector ColourGreenBlue
Polish TypeAngled Physical ContactUltra Physical Contact
Back ReflectionLowerHigher
FTTH / PONVery CommonUsed
CATVExcellentLess preferred
Enterprise LANApplication dependentVery Common
Direct APC-to-UPC MatingNoNo

Always match APC connectors with APC interfaces and UPC connectors with UPC interfaces.

Fibre Pigtail vs Fibre Patch Cord

FeatureFibre PigtailFibre Patch Cord
Connectorized Ends12
Bare Fibre EndYesNo
Requires SplicingYesNo
Primary PurposeFibre terminationEquipment interconnection
ODF InstallationExcellentUsed after termination
FDB InstallationExcellentApplication dependent
Factory-Polished ConnectorOne endBoth ends
Typical LengthShortWide range

Why Use an SC/APC Pigtail?

Factory-Polished Connector

The SC/APC connector is polished under controlled manufacturing conditions before installation.

Low Back Reflection

The APC angled polish helps reduce reflected optical signals.

Professional Fusion-Splice Termination

The bare end can be fusion-spliced to installed single-mode fibre to create a reliable permanent termination.

OS2 Single Mode Performance

Single-mode OS2 fibre provides excellent low-loss performance for telecommunications and access networks. 

Bend-Insensitive Fibre Options

G.657A1 and similar fibres make routing easier inside compact fibre boxes and trays. 

Easy Identification

The green connector immediately distinguishes SC/APC from blue SC/UPC.

Simplex Construction

One pigtail can terminate each individual core of a multi-core fibre cable.

Watch SC/APC Single Mode Fibre Pigtail

Watch on YouTube: https://youtu.be/pXkRAniethg

The SC/APC Single Mode Fibre Pigtail provides a professional method of creating SC/APC connectorized termination points from bare single-mode fibre. The pigtail normally consists of one yellow fibre with a green SC/APC connector at one end and an unterminated fibre tail at the other. Current CommScope products confirm this arrangement using single-mode G.652.D and G.657.A1 fibre. 

The APC connector is particularly useful in optical networks where reflected light needs to be minimized. This makes the pigtail highly suitable for FTTH, PON, CATV, fibre distribution and telecommunications networks. The pigtail can be fusion-spliced to the installed fibre and organized inside an ODF, splice tray or distribution enclosure while the connector remains accessible at the adapter panel.

Using a factory-terminated pigtail also simplifies professional fibre installations because technicians only need to prepare and splice the bare end. Fiber Optics Kenya can supply SC/APC pigtails alongside SC/APC adapters, splice protection sleeves, ODFs, FDB boxes, PLC splitters, fibre splice trays, SC/APC patch cords and fibre testing equipment, making it easier to source a complete termination solution.

Applications of SC/APC Single Mode Fibre Pigtail

1. FTTH Networks

Terminate subscriber or distribution fibre where SC/APC connectivity is required.

2. GPON Networks

Ideal for passive optical network installations using APC connector interfaces.

3. Optical Distribution Frames

Fusion-splice incoming fibre to the pigtail and mount the SC/APC connector in an adapter.

4. Fibre Distribution Boxes

Create organized SC/APC termination points inside FDBs.

5. PLC Splitter Installations

Connect fibre infrastructure to SC/APC-terminated PON splitters.

6. Telecommunications Networks

Provide permanent single-mode fibre termination in telecom installations.

7. ISP Infrastructure

Use in distribution cabinets, ODFs and access-network enclosures.

8. CATV Networks

APC polishing is particularly useful where low return reflection is important.

9. Fibre Joint Closures

Provide connectorized termination where the network design requires it.

10. Fibre Testing and Maintenance

Create standardized SC/APC interfaces for compatible test equipment.

Typical ODF Termination Process

StepInstallation Process
1Route fibre cable into ODF
2Remove outer cable sheath
3Separate the fibre to be terminated
4Prepare SC/APC pigtail bare end
5Strip and clean both fibres
6Precision-cleave fibre ends
7Fusion-splice fibres together
8Install splice protection sleeve
9Place splice inside tray
10Route pigtail neatly
11Insert SC/APC connector into adapter
12Test optical loss

SC/APC Pigtail vs Fast Connector

FeatureSC/APC Pigtail + Fusion SpliceSC/APC Fast Connector
Connector PolishFactory polishedFactory-prepared internal interface
Joint TypeFusion spliceMechanical field termination
ConsistencyExcellent when properly installedInstaller dependent
Fusion Splicer RequiredYesNo
Installation SpeedModerateFaster
ODF InstallationExcellentGood
Permanent Fibre InfrastructureExcellentGood
Large Professional ProjectsCommonUseful for rapid deployment

Recommended Accessories

AccessoryPurpose
SC/APC AdapterCouples compatible SC/APC connectors
Fusion Splice SleeveProtects completed splice
Fibre Splice TrayOrganizes fibres and splices
Optical Distribution FrameStructured fibre termination
Fibre Distribution BoxProtects fibre termination points
PLC SplitterSplits PON optical signals
SC/APC Patch CordConnects terminated fibre to equipment
Fibre StripperRemoves fibre coating
Precision Fibre CleaverPrepares fibre for fusion
Fusion SplicerCreates permanent optical splice
Optical Power MeterMeasures fibre signal level
PON Power MeterTests PON signals
Visual Fault LocatorAssists fibre fault tracing
OTDRTests fibre link performance
SC/APC Connector CleanerCleans connector end faces

Why Buy SC/APC Single Mode Fibre Pigtail from Fiber Optics Kenya?

Single Mode pigtails SC/APC - 1.5 meters | Tronik Gadgets Store
Why Choose Fiber Optics Kenya?Customer Benefit
SC/APC Pigtail OptionsSuitable for professional fibre termination
Single Mode OS2 OptionsExcellent optical performance
G.657 Fibre OptionsImproved bend performance
Multiple LengthsMatch different enclosure sizes
SC/APC AdaptersCompatible termination accessories
ODFs & FDBsComplete fibre-distribution systems
PLC SplittersPON network components available
Splicing AccessoriesComplete installation solution
Testing EquipmentSupport commissioning and maintenance
Technical GuidanceHelp choosing compatible components
Bulk SupplySuitable for ISPs and contractors
Nationwide DeliverySupply throughout Kenya

Frequently Asked Questions

What is an SC/APC Single Mode Fibre Pigtail?

It is a single-mode fibre lead with an SC/APC connector on one end and bare fibre on the other, designed mainly for splicing and fibre termination.

What colour is an SC/APC connector?

SC/APC connectors are normally green.

What colour is single-mode pigtail fibre?

Single-mode pigtails are commonly yellow.

Is SC/APC single mode?

Yes. CommScope currently lists SC/APC single-mode fibre pigtails using G.652.D and G.657.A1 fibre. 

What fibre size is normally used?

Typical single-mode pigtails use approximately 9/125 µm fibre.

What does APC mean?

APC means Angled Physical Contact.

Why is APC used?

The angled connector end face reduces optical back reflection, making APC useful in networks such as PON and CATV.

What is the difference between SC/APC and SC/UPC?

SC/APC uses an angled end face and is normally green, while SC/UPC uses an Ultra Physical Contact polish and is usually blue.

Can SC/APC connect directly to SC/UPC?

No. Their connector geometries differ and they should not be directly mated.

What is G.652D fibre?

G.652D is a widely used conventional single-mode fibre standard suitable for telecommunications and long-distance optical networks.

What is G.657A1 fibre?

G.657A1 is a bend-insensitive single-mode fibre designed to provide improved performance around tighter bends. CommScope lists G.657.A1 among its current SC/APC pigtail fibre types. 

Is SC/APC suitable for FTTH?

Yes. SC/APC is widely suitable for FTTH and passive optical network termination.

Is it suitable for GPON?

Yes. SC/APC is commonly used in GPON installations.

Can it be installed in an ODF?

Yes. ODF termination is one of the main applications of a fibre pigtail.

Does it require fusion splicing?

Normally yes. The unterminated end is fusion-spliced to the installed fibre.

Can it be used in an FDB?

Yes. It is suitable for fibre distribution boxes requiring SC/APC outputs.

What is the difference between a pigtail and a patch cord?

A pigtail has one connector and one bare fibre end, while a patch cord has connectors on both ends.

Do you supply SC/APC adapters?

Yes. Fiber Optics Kenya can supply matching SC/APC adapters and termination accessories.

Do you supply PLC splitters?

Yes. Compatible PLC splitters and PON accessories can be supplied.

Do you supply ODFs and fibre boxes?

Yes. Compatible ODFs, FDBs, splice trays and fibre enclosures can be supplied.

Do you provide fibre splicing and testing?

Yes. Professional fibre fusion splicing, termination and testing support is available.

Do you deliver outside Nairobi?

Yes. Fiber Optics Kenya supplies fibre optic products and accessories throughout Kenya.

Contact Fiber Optics Kenya

Fiber Optics Kenya
Lyric House
7th Floor, Room S9
Kimathi Street
Nairobi

Phone: +254 704 991 492
Email: info@fibreopticskenya.co.ke

The SC/APC Single Mode Fibre Pigtail provides a reliable, low-reflection solution for fusion-splice termination in FTTH, PON, ODF and telecommunications networks.

Contact Fiber Optics Kenya for competitive pricing, SC/APC accessories, ODFs, fibre termination products, bulk orders and nationwide delivery across Kenya.