The SC/APC Simplex Single Mode Fibre Pigtail 9/125 is a factory-terminated optical fibre lead designed for fusion splicing into single-mode fibre networks. Unlike a patch cord, which has connectors on both ends, a pigtail has an SC/APC connector on one end and a bare fibre end on the other, allowing installers to splice it directly to incoming or outgoing fibre inside an ODF, fibre distribution box, splice tray or termination enclosure.
Typical versions use 9/125 µm OS2 single-mode fibre, commonly G.652D or bend-insensitive G.657A1. Commercial SC/APC pigtails are available with 0.9 mm tight-buffered fibre, green APC connectors and yellow single-mode jackets. Current product families specifically include SC/APC, 9/125 µm, G.657A1 single-mode pigtails in 1 m and 2 m lengths.
At Fiber Optics Kenya, SC/APC Simplex Single Mode Fibre Pigtails 9/125 are suitable for FTTH installations, GPON networks, fibre ODFs, FDBs, joint closures, telecom systems, ISP networks and general single-mode fibre termination. Compatible SC/APC adapters, PLC splitters, splice sleeves, fibre trays, ODFs, FTTH boxes and other installation accessories can also be supplied.
Key Product Specifications
| Specification | Details |
|---|---|
| Product Name | SC/APC Simplex Single Mode Fibre Pigtail 9/125 |
| Product Type | Fibre Optic Pigtail |
| Connector Type | SC/APC |
| Connector Polish | APC |
| Connector Colour | Green |
| Fibre Mode | Single Mode |
| Typical Fibre Category | OS2 |
| Fibre Size | 9/125 µm |
| Common Fibre Standards | G.652D / G.657A1 / G.657A2 |
| Configuration | Simplex |
| Fibre Count | 1 |
| Termination | Connector at one end, bare fibre at other |
| Common Buffer Diameter | 0.9 mm |
| Typical Jacket / Buffer Colour | Yellow |
| Common Lengths | 1 m / 2 m / 3 m depending on model |
| Common Wavelengths | 1310 nm / 1550 nm |
| Typical Insertion Loss | ≤0.2–0.3 dB depending on model |
| Typical APC Return Loss | ≥60 dB, often around 65 dB |
| Installation Method | Fusion splicing |
| Applications | FTTH, PON, ODF, FDB, telecom, ISP |
| Professional Installation | Available |
| Delivery | Available throughout Kenya |
A current SC/APC pigtail specification identifies the cable as 9/125 µm OS2 single mode, G.657A1, 0.9 mm jacket and 2 m total length.
What Is a Fibre Pigtail?

A fibre pigtail is different from a standard fibre patch cord because only one end is connectorized.
| Feature | Fibre Pigtail |
|---|---|
| Connectorized Ends | One |
| Bare Fibre End | Yes |
| Primary Installation Method | Fusion splicing |
| Typical Location | ODF, FDB, termination box, splice tray |
| Purpose | Terminate installed fibre with a factory-polished connector |
| Common Length | 1–3 metres |
| Simplex Version | One optical fibre |
The bare end is fusion-spliced to the installed fibre, while the SC/APC connector plugs into an SC/APC adapter.
What Does SC/APC Simplex Single Mode 9/125 Mean?

| Term | Meaning |
|---|---|
| SC | Standard / Subscriber Connector |
| APC | Angled Physical Contact |
| SC/APC | SC connector with angled-polished end face |
| Simplex | One optical fibre |
| Single Mode | Fibre designed for single-mode optical transmission |
| 9/125 | Approx. 9 µm core and 125 µm cladding |
| Pigtail | Connector on one end, bare fibre on the other |
| OS2 | Single-mode fibre category |
SC/APC Connector Features
| Feature | Description |
|---|---|
| Connector Housing | Green |
| Ferrule Type | Ceramic commonly |
| Ferrule Diameter | Approx. 2.5 mm |
| Polish Type | APC |
| End-Face Angle | Approximately 8° commonly |
| Connection Style | Push-Pull |
| Return Loss | Excellent |
| FTTH Suitability | Excellent |
| PON Suitability | Excellent |
| CATV Suitability | Excellent |
APC pigtails are specifically useful where back reflection must be minimized. Representative SC/APC pigtail specifications list APC return loss of 60 dB or higher, with some products specifying approximately 65 dB.
9/125 Single Mode Fibre Explained
The 9/125 designation describes the approximate size of the fibre core and cladding.
| Fibre Component | Approximate Diameter |
|---|---|
| Optical Core | 9 µm |
| Cladding | 125 µm |
| Typical Tight Buffer | 900 µm / 0.9 mm |
The small core of single-mode fibre allows optical signals to travel over much greater distances than conventional multimode fibre.
G.652D vs G.657A1 Fibre Pigtail
| Feature | G.652D | G.657A1 |
|---|---|---|
| Fibre Mode | Single Mode | Single Mode |
| Typical Size | 9/125 µm | 9/125 µm |
| Long-Distance Transmission | Excellent | Excellent |
| Bend Performance | Standard | Improved |
| FTTH Installations | Good | Excellent |
| ODF Termination | Excellent | Excellent |
| Compact Fibre Boxes | Good | Better |
| Indoor Routing | Excellent | Excellent |
Both types are commercially available in SC/APC pigtail form. One current supplier lists SC/APC 0.9 mm products in both G.652D and G.657A1 versions.
G.657A1 vs G.657A2
| Feature | G.657A1 | G.657A2 |
|---|---|---|
| Single Mode | Yes | Yes |
| Bend Insensitive | Yes | Yes |
| Tight-Bend Performance | Excellent | Enhanced |
| FTTH Use | Excellent | Excellent |
| Distribution Boxes | Excellent | Excellent |
| Compact Enclosures | Very Good | Better |
| Compatibility with Conventional SMF | Excellent | Excellent |
A current G.657A1 SC/APC pigtail specification notes bend-insensitive fibre designed to reduce bending loss and tolerate tight routing down to a 7.5 mm radius under the cited construction.
Typical Optical Performance
| Optical Parameter | Typical / Representative Value |
|---|---|
| Fibre Mode | Single Mode |
| Fibre Size | 9/125 µm |
| Common Fibre Type | G.652D / G.657A1 |
| Connector Type | SC/APC |
| Operating Wavelength | 1310 nm |
| Operating Wavelength | 1550 nm |
| Insertion Loss | ≤0.2–0.3 dB |
| APC Return Loss | ≥60 dB |
| Typical Premium APC Return Loss | Around ≥65 dB |
| Repeatability | Typically low-loss and stable |
| Fibre Attenuation | Low, fibre-grade dependent |
One published fibre-pigtail specification gives single-mode insertion loss up to 0.25 dB and APC return loss ≥60 dB, typically 65 dB.
Typical Mechanical Characteristics
| Parameter | Typical / Representative Description |
|---|---|
| Configuration | Simplex |
| Number of Fibres | 1 |
| Buffer Diameter | 0.9 mm commonly |
| Connector | SC/APC |
| Connector Colour | Green |
| Buffer Colour | Yellow |
| Fibre Type | OS2 9/125 |
| Jacket / Buffer Material | LSZH / PVC depending on model |
| Available Length | 1–3 m commonly |
| Ferrule Material | Ceramic |
| Splicing Method | Fusion splice |
| Operating Temperature | Model dependent |
Current products include 0.9 mm G.657A1 SC/APC pigtails in multiple lengths.
Why Use a Fibre Pigtail Instead of a Fast Connector?

| Feature | Fibre Pigtail + Fusion Splice | Fast Connector |
|---|---|---|
| Connector Polish | Factory polished | Field assembled |
| Installation Method | Fusion splicing | Mechanical termination |
| Insertion-Loss Consistency | Excellent | Installation dependent |
| Long-Term Reliability | Excellent | Good when properly installed |
| Tools Required | Fusion splicer | Cleaver/stripper and connector tools |
| ODF Termination | Excellent | Good |
| Large Professional Networks | Preferred commonly | Useful |
| Repair / Quick Installation | More involved | Faster |
For professional ODF and distribution installations, fusion-spliced pigtails are widely used because the connector end is factory polished while only the bare fibre needs to be spliced.
SC/APC vs SC/UPC Fibre Pigtail
| Feature | SC/APC | SC/UPC |
|---|---|---|
| Connector Colour | Green | Blue |
| Polish Type | Angled Physical Contact | Ultra Physical Contact |
| Back Reflection | Lower | Higher |
| FTTH / PON | Very Common | Used |
| CATV | Excellent | Less preferred |
| Enterprise Ethernet | Application dependent | Very Common |
| Can APC Mate Directly to UPC? | No | No |
SC/APC and SC/UPC should not be directly mated because their ferrule end-face geometries differ.
Pigtail vs Patch Cord
| Feature | Fibre Pigtail | Fibre Patch Cord |
|---|---|---|
| Connector Ends | One | Two |
| Bare Fibre End | Yes | No |
| Requires Splicing | Yes | No |
| Main Use | Fibre termination | Equipment interconnection |
| ODF Installation | Excellent | Used after termination |
| FDB Installation | Excellent | Application dependent |
| Factory Polished Connector | Yes | Yes |
| Typical Length | Short | Wide range |
Key Benefits of SC/APC Simplex Single Mode Fibre Pigtail 9/125
Factory-Polished SC/APC Connector
The connector is polished during manufacturing, helping provide reliable and consistent optical performance.
Low Back Reflection
The APC angled connector provides excellent return-loss performance, which is especially valuable in PON and FTTH systems.
9/125 Single-Mode Fibre
Single-mode fibre provides low attenuation and excellent performance for long-distance optical networks.
Bend-Insensitive Options
G.657A1 and G.657A2 versions are suitable for compact ODFs and FTTH termination boxes.
Ideal for Fusion Splicing
The bare fibre end is designed to be spliced directly to installed optical fibre.
Easy Identification
The green connector indicates APC, while the yellow fibre buffer commonly identifies single-mode fibre.
Professional Fibre Termination
Pigtails provide a clean way to convert installed bare fibre into a standardized SC/APC interface.
Watch SC/APC Simplex Single Mode Fibre Pigtail 9/125
Watch on YouTube: https://www.youtube.com/shorts/Uaon3nJ4Gfg?feature=share
The SC/APC Simplex Single Mode Fibre Pigtail 9/125 provides a professional method of terminating installed single-mode fibre inside ODFs, distribution boxes and fibre enclosures. One end comes factory terminated with a green SC/APC connector, while the opposite end remains bare for fusion splicing. Commercial versions are readily available in both G.652D and bend-insensitive G.657A1 fibre.
Using G.657A1 bend-insensitive single-mode fibre is particularly useful in modern FTTH installations because fibre often has to be routed around splice trays and inside compact termination boxes. One current SC/APC pigtail platform uses 900 µm LSOH tight-buffered G.657A1 fibre and is specifically designed to reduce bending loss.
The SC/APC connector's low-reflection angled polish also makes it well suited to FTTH, PON and other optical systems where return loss matters. Fiber Optics Kenya can supply these pigtails together with SC/APC adapters, splice sleeves, ODFs, FDB boxes, PLC splitters, fibre splice trays and testing accessories, allowing installers to source the main components required for professional fibre termination.
Applications of SC/APC Simplex Single Mode Fibre Pigtail 9/125
1. Fibre Optic ODFs
Fusion splice incoming fibre onto the pigtail and connect the SC/APC end to an adapter.
2. FTTH Networks
Terminate distribution and subscriber fibre inside fibre boxes and ODFs.
3. GPON Networks
Suitable for PON infrastructure requiring SC/APC interfaces.
4. Fibre Distribution Boxes
Create organized connectorized outputs from incoming bare fibres.
5. Fibre Joint Closures
Terminate selected fibres where connectorized access is required.
6. Telecommunications Networks
Suitable for single-mode optical termination within telecom infrastructure.
7. ISP Networks
Use inside ODFs, cabinets and distribution enclosures.
8. CATV Fibre Networks
APC connectors help minimize optical reflections.
9. Enterprise Fibre Networks
Useful wherever SC/APC termination is specified.
10. Fibre Testing and Maintenance
Provides a standardized connector interface after fusion splicing.
Typical ODF Termination Process
| Step | Process |
|---|---|
| 1 | Route incoming fibre cable into the ODF |
| 2 | Strip the fibre cable |
| 3 | Prepare the selected optical fibre |
| 4 | Strip the pigtail bare end |
| 5 | Cleave both fibres |
| 6 | Fusion splice the fibres |
| 7 | Protect splice with heat-shrink sleeve |
| 8 | Place splice inside splice tray |
| 9 | Plug SC/APC connector into adapter |
| 10 | Test optical loss |
Recommended Accessories
| Accessory | Purpose |
|---|---|
| SC/APC Adapter | Connects the pigtail to patch cord/equipment |
| Fusion Splice Sleeve | Protects the fusion splice |
| Fibre Splice Tray | Organizes pigtails and splices |
| Fibre ODF | Provides structured fibre termination |
| FDB / FAT Box | Outdoor or indoor fibre distribution |
| PLC Splitter | Splits PON optical signal |
| SC/APC Patch Cord | Connects terminated fibre to equipment |
| Fibre Stripper | Removes fibre coatings |
| Fibre Cleaver | Prepares fibres before fusion |
| Fusion Splicer | Joins installed fibre to pigtail |
| Optical Power Meter | Checks optical signal level |
| Visual Fault Locator | Assists basic fault tracing |
| OTDR | Tests fibre link condition |
| Connector Cleaner | Keeps SC/APC ferrule clean |
Why Buy SC/APC Simplex Single Mode Fibre Pigtail 9/125 from Fiber Optics Kenya?

| Why Choose Fiber Optics Kenya? | Customer Benefit |
|---|---|
| SC/APC Pigtails | Suitable for PON and FTTH termination |
| 9/125 Single Mode | Professional optical transmission |
| G.657 Fibre Options | Better bend performance |
| Multiple Length Options | Match different ODF and enclosure sizes |
| SC/APC Adapters | Compatible termination accessories |
| Splice Accessories | Build complete fibre termination points |
| ODFs & FDBs | Complete distribution solutions |
| PLC Splitters | PON components available |
| Technical Guidance | Help selecting compatible fibre products |
| Bulk Supply | Suitable for ISPs and installers |
| Competitive Pricing | Cost-effective project procurement |
| Nationwide Delivery | Supply throughout Kenya |
Frequently Asked Questions
What is an SC/APC Simplex Single Mode Fibre Pigtail 9/125?
It is a single-mode fibre lead with an SC/APC connector on one end and bare fibre on the other, designed primarily for fusion-splice termination.
What does 9/125 mean?
It refers to an approximately 9 µm optical core and 125 µm cladding.
What does simplex mean?
Simplex means the pigtail contains one optical fibre.
What colour is the SC/APC connector?
SC/APC connectors are typically green.
What colour is the fibre?
Single-mode pigtails commonly use a yellow buffer or jacket.
What is the difference between a pigtail and patch cord?
A pigtail has a connector on only one end and requires splicing. A patch cord has connectors on both ends and can be plugged in directly.
What fibre type is commonly used?
Commercial SC/APC pigtails are available using G.652D and G.657A1 9/125 µm fibre.
Is G.657A1 suitable for FTTH?
Yes. G.657A1 is bend-insensitive and well suited to compact FTTH fibre routing.
What is the common pigtail diameter?
A 0.9 mm / 900 µm tight buffer is very common.
What is the typical insertion loss?
Depending on product quality, single-mode pigtails commonly specify approximately 0.2–0.3 dB or less.
What is the typical APC return loss?
Representative APC pigtails specify ≥60 dB, with some products around 65 dB.
Is it suitable for GPON?
Yes. SC/APC single-mode fibre termination is commonly suited to GPON and other PON infrastructure.
Can it be installed in an ODF?
Yes. ODF termination is one of the primary applications of fibre pigtails.
Does it require fusion splicing?
Normally yes. The bare fibre end is typically fusion-spliced to the installed fibre.
Can it be used in an FDB?
Yes. It is suitable for fibre distribution and termination boxes where SC/APC connectorized outputs are required.
Can SC/APC connect directly to SC/UPC?
No. APC and UPC ferrule geometries differ and should not be directly mated.
Are different lengths available?
Yes. Commercial SC/APC pigtails are available in 1 m, 2 m, 3 m and other lengths, depending on manufacturer.
Do you supply SC/APC adapters?
Yes. Fiber Optics Kenya can supply matching SC/APC adapters and fibre termination accessories.
Do you supply splice sleeves?
Yes. Fusion splice protection sleeves can be supplied for ODF and FDB installations.
Do you supply ODFs and fibre boxes?
Yes. Compatible ODFs, FDBs, FAT boxes and fibre enclosures can be supplied.
Do you supply fusion-splicing tools?
Yes. Fibre splicing and testing accessories can be supplied according to installation requirements.
Do you provide fibre installation and termination?
Yes. Professional fibre installation, fusion splicing, termination and testing support is available.
Do you deliver outside Nairobi?
Yes. Fiber Optics Kenya supplies fibre optic products and accessories throughout Kenya.
Contact Fiber Optics Kenya
Fiber Optics Kenya
Lyric House
7th Floor, Room S9
Kimathi Street
Nairobi
Phone: +254 704 991 492
Email: info@fibreopticskenya.co.ke
The SC/APC Simplex Single Mode Fibre Pigtail 9/125 provides a clean, low-loss solution for fusion-splice termination in FTTH, PON, ODF and telecommunications networks.
Contact Fiber Optics Kenya for competitive pricing, SC/APC accessories, ODFs, fibre termination products, bulk orders and nationwide delivery across Kenya.