SC Fibre Adapters Price in Kenya
1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails in Kenya
KSh 3,500.00
1 available
Continue shopping1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails in Kenya
The 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails is a high-capacity fibre distribution enclosure designed to organize optical splitting, fibre splicing, termination, storage and subscriber connections in one protected location. It is particularly useful for FTTH and other passive optical networks where one incoming feeder fibre needs to be distributed to as many as 32 downstream fibre connections.
A typical loaded configuration combines a 1x32 PLC splitter, SC/UPC adapters and matching single-mode pigtails inside the terminal box. The blue SC/UPC interfaces provide convenient connectorized access for subscriber fibres, while the internal pigtails simplify fusion-splice termination. Commercial 32-core FTTH distribution boxes are available with 1x32 SC/UPC splitter configurations and organized pigtail routing for high-density fibre deployments.
At Fiber Optics Kenya, the 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails is ideal for ISPs, telecommunications contractors, fibre installers, residential estates, apartment buildings, offices and commercial developments. Matching SC/UPC patch cords, fast connectors, FTTH drop cables, splice sleeves, fibre cleaning accessories and optical testing equipment can also be supplied.
Key Product Specifications
| Specification | Details |
|---|---|
| Product Name | 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails |
| Product Type | Fibre Terminal / Distribution Box |
| Distribution Capacity | Up to 32 Fibres |
| Splitter Configuration | 1x32 |
| Splitter Technology | PLC |
| Splitter Inputs | 1 |
| Splitter Outputs | 32 |
| Adapter Type | SC/UPC |
| Typical Adapter Colour | Blue |
| Pigtails | SC/UPC Single Mode |
| Typical Adapter Capacity | Up to 32 |
| Fibre Mode | Single Mode |
| Typical Fibre Category | OS2 |
| Typical Fibre Type | G.657A / G.652D depending on components |
| Ideal Power per Output | Approx. 3.125% |
| Theoretical Split Loss | Approx. 15.05 dB |
| Operating Wavelength | Typically 1260–1650 nm |
| Typical 1x32 Insertion Loss | Around 16–17.5 dB |
| Splicing Capability | Yes |
| Pigtail Termination | Yes |
| Fibre Storage | Yes |
| Drop Cable Management | Yes |
| Typical Installation | Wall Mount |
| Outdoor Options | Available depending on enclosure |
| Electrical Power Required | No |
| Applications | FTTH, GPON, EPON, FTTx, PON |
| Professional Installation | Available |
| Delivery | Available throughout Kenya |
A 32-position fibre termination enclosure can support up to 32 SC-format adapters and pigtail-based termination, while a 1x32 PLC splitter divides one optical signal into 32 equal downstream signals.
What Is a 1x32 Fibre Terminal Box?

The terminal box provides a central location for managing feeder fibre, splitter outputs, pigtails and subscriber connections.
| Component | Function |
|---|---|
| Outer Enclosure | Protects fibre components |
| Feeder Cable Entry | Receives incoming fibre |
| Splice Tray | Stores fusion splices |
| 1x32 PLC Splitter | Divides one signal into 32 outputs |
| SC/UPC Pigtails | Provide internal terminations |
| SC/UPC Adapters | Provide external fibre ports |
| Fibre Routing Guides | Organize optical fibres |
| Drop Cable Ports | Route subscriber connections |
| Cable Clamps | Secure fibre cables |
| Service Loop Area | Stores excess fibre |
A current 32-core SC/UPC FAT box visibly integrates 32 blue SC/UPC connections with neatly managed internal fibre leads.
What Does 1x32 Mean?
| Term | Meaning |
|---|---|
| 1x32 | One optical input split into 32 outputs |
| SC | Standard / Subscriber Connector |
| UPC | Ultra Physical Contact |
| PLC | Planar Lightwave Circuit |
| Pigtail | Short terminated fibre used for splicing |
| FTTH | Fibre to the Home |
| GPON | Gigabit Passive Optical Network |
| PON | Passive Optical Network |
One 1x32 PLC splitter can provide 32 downstream optical branches from a single feeder fibre.
How the 1x32 Terminal Box Works
| Stage | Function |
|---|---|
| Incoming Feeder Fibre | Brings signal from network |
| PLC Splitter Input | Receives optical power |
| 1x32 Splitter | Divides signal into 32 paths |
| Splitter Outputs | Feed internal terminations |
| SC/UPC Pigtails | Fusion-splice network fibres |
| SC/UPC Adapters | Provide accessible ports |
| Subscriber Drop Fibres | Connect customers |
| ONT / ONU | Receives subscriber optical service |
The splitter operates passively and therefore requires no electrical power, power supply or configuration software.
1x32 Optical Distribution
| Parameter | Value |
|---|---|
| Inputs | 1 |
| Outputs | 32 |
| Ideal Power Share per Output | 3.125% |
| Theoretical Split Loss | ~15.05 dB |
| Typical Practical Insertion Loss | ~16–17.5 dB |
| Potential Subscriber Branches | 32 |
| Power Requirement | None |
A 1x32 splitter is intended for high-density subscriber distribution, so its optical loss must be incorporated carefully into the total network power budget.
SC/UPC Adapter Features
| Feature | Benefit |
|---|---|
| Typical Blue Colour | Easy UPC identification |
| SC Form Factor | Common telecom interface |
| UPC Polish | Low optical reflection |
| Push-Pull Connection | Easy connection |
| Single-Mode Compatibility | Excellent |
| Patch Cord Compatibility | Excellent |
| Easy Maintenance | Ports can be cleaned and reconnected |
| High Port Count | Suitable for 32-way distribution |
The product images show the characteristic blue SC/UPC adapter arrangement commonly used in fibre terminal boxes.
Role of Fibre Pigtails
A fibre pigtail has a connector on one end and bare fibre on the other, allowing it to be fusion-spliced into the installed fibre network.
| Pigtail Feature | Benefit |
|---|---|
| SC/UPC Connector | Matches terminal-box adapters |
| Bare Splice End | Enables fusion splicing |
| Single-Mode Fibre | Suitable for FTTH |
| Colour Coding | Helps identify fibres |
| Factory Connector | Reliable optical termination |
| Compact Routing | Easy box management |
Pigtails allow technicians to create permanent internal fusion splices while still providing removable connectorized interfaces at the adapter panel.
Loaded Terminal Box vs Empty Terminal Box

| Feature | Loaded SC/UPC Box | Empty Box |
|---|---|---|
| Enclosure | Included | Included |
| SC/UPC Adapters | Included | Usually Not |
| Pigtails | Included | Usually Not |
| 1x32 Splitter | Included/configured where specified | Usually Not |
| Ready for Distribution | Higher | Requires Assembly |
| Installation Time | Faster | Longer |
| Customization | Moderate | Excellent |
| Field Work | Reduced | Greater |
The loaded version is particularly useful for rapid FTTH deployment and standardized ISP installations.
SC/UPC vs SC/APC Terminal Box
| Feature | SC/UPC | SC/APC |
|---|---|---|
| Typical Colour | Blue | Green |
| Polish | Ultra Physical Contact | Angled Physical Contact |
| Back Reflection | Low | Lower |
| FTTH Use | Supported | Very Common |
| LAN Fibre Networks | Excellent | Application dependent |
| CATV | Less Preferred | Excellent |
| Direct UPC/APC Mating | No | No |
Always use connectors and adapters with matching polish types.
1x16 vs 1x32 Fibre Terminal Box
| Feature | 1x16 | 1x32 |
|---|---|---|
| Optical Outputs | 16 | 32 |
| Ideal Power per Output | 6.25% | 3.125% |
| Theoretical Split Loss | ~12.04 dB | ~15.05 dB |
| Potential Subscribers | 16 | 32 |
| Optical Budget Requirement | High | Higher |
| Subscriber Density | Medium | High |
| Large FTTH Deployment | Good | Excellent |
The 1x32 configuration provides twice the downstream capacity of 1x16 but adds approximately 3 dB more theoretical splitting loss.
1x8 vs 1x32 Fibre Terminal Box
| Feature | 1x8 | 1x32 |
|---|---|---|
| Outputs | 8 | 32 |
| Ideal Power per Output | 12.5% | 3.125% |
| Theoretical Split Loss | ~9.03 dB | ~15.05 dB |
| Small Subscriber Cluster | Excellent | Often Oversized |
| Large Estate Deployment | Limited | Excellent |
| Optical Budget | More Flexible | More Demanding |
32-Port Adapter Capacity
| Adapter Group | Typical Subscriber Allocation |
|---|---|
| Ports 1–8 | Subscribers 1–8 |
| Ports 9–16 | Subscribers 9–16 |
| Ports 17–24 | Subscribers 17–24 |
| Ports 25–32 | Subscribers 25–32 |
A 32-position termination enclosure can accommodate up to 32 SC-shaped adapters.
Typical Internal Fibre Management
| Internal Feature | Function |
|---|---|
| Splice Tray | Stores fibre splices |
| Pigtail Routing Area | Organizes pigtails |
| Adapter Panel | Holds SC/UPC adapters |
| Splitter Mount | Secures 1x32 splitter |
| Fibre Rings | Controls service loops |
| Cable Clamps | Secures feeder fibre |
| Drop Cable Outputs | Routes subscriber fibres |
| Port Labels | Identifies each connection |
Proper fibre routing helps protect against excessive bending and makes maintenance easier.
Key Benefits of 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails
High Subscriber Capacity
One distribution point can provide up to 32 fibre outputs.
Integrated Fibre Splitting
A 1x32 PLC splitter efficiently distributes one feeder signal to multiple downstream paths.
Ready SC/UPC Interfaces
Blue SC/UPC ports provide standardized connectorized subscriber access.
Pigtail-Based Termination
Pigtails allow clean fusion-splice termination inside the enclosure.
Organized Fibre Management
The box keeps splices, splitter outputs, pigtails and subscriber cables protected.
Faster Deployment
A loaded enclosure reduces the amount of assembly required in the field.
Passive Operation
No electrical power is required.
Watch 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails
Watch on YouTube: https://youtu.be/q-JRq_05tCY
The 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails provides a structured way to combine fibre splitting, splicing and connectorized distribution within one enclosure. A 32-port box can accommodate SC-format adapter positions, while the SC/UPC pigtails create reliable internal fusion-splice termination points for installed fibres.
When configured with a 1x32 PLC splitter, one incoming optical signal can be distributed across thirty-two outputs. This makes the terminal box especially useful for high-density FTTH networks, although the relatively high optical loss of a 1x32 split means that fibre length, splice loss, connector loss and engineering margin should all be calculated carefully.
For ISPs and fibre installers, the loaded adapter-and-pigtail design can simplify both initial installation and future maintenance. Fiber Optics Kenya can supply the 1x32 Fibre Terminal Box together with SC/UPC patch cords, replacement pigtails, fast connectors, FTTH drop cables, fibre-cleaning tools, fusion-splicing accessories and optical testing equipment for complete fibre distribution projects.
Applications
1. FTTH Networks
Provides high-density subscriber fibre distribution.
2. GPON Networks
Supports passive one-to-many optical distribution between OLT and ONTs.
3. EPON Networks
Suitable for compatible passive optical access architectures.
4. Residential Estates
Provides fibre distribution to clusters of homes.
5. Apartment Buildings
Supports numerous apartment or tenant connections from one distribution point.
6. Commercial Buildings
Provides fibre termination and distribution for offices and tenants.
7. ISP Access Networks
Creates standardized high-capacity subscriber distribution points.
8. Campus Networks
Provides structured fibre distribution to multiple endpoints.
9. Telecommunications Networks
Supports protected fibre splitting and termination.
10. PON Distribution Projects
Combines splitter, pigtails and adapter ports inside one enclosure.
Typical FTTH Architecture
| Network Stage | Typical Component |
|---|---|
| OLT | Service Provider Equipment |
| Feeder Network | Single Mode Fibre |
| Terminal Box Input | Feeder Fibre |
| PLC Splitter | 1x32 |
| Pigtails | SC/UPC |
| Adapter Interfaces | Up to 32 SC/UPC |
| Subscriber Fibre | FTTH Drop Cable |
| Customer Equipment | ONT / ONU |
Optical Budget Considerations
| Loss Source | Include in Calculation? |
|---|---|
| 1x32 PLC Splitter | Yes |
| Feeder Fibre | Yes |
| Distribution Fibre | Yes |
| Drop Cable | Yes |
| Fusion Splices | Yes |
| SC/UPC Connectors | Yes |
| Adapters | Yes |
| Other Splitters | Yes |
| Engineering Margin | Yes |
The 1x32 splitter is usually one of the largest sources of loss in the optical path, so power-budget planning is particularly important.
Installation Considerations
| Installation Factor | Recommendation |
|---|---|
| Connector Type | Maintain SC/UPC compatibility |
| Pigtail Splicing | Use quality fusion splicing |
| Connector Cleaning | Clean before mating |
| Port Labelling | Clearly number 1–32 |
| Fibre Bend Radius | Avoid tight routing |
| Splice Protection | Use splice protection sleeves |
| Unused Ports | Keep dust caps installed |
| Cable Entry | Secure feeder cable |
| Output Testing | Test each activated port |
| Documentation | Record subscriber-port assignments |
Recommended Accessories
| Accessory | Purpose |
|---|---|
| SC/UPC Patch Cord | Connects terminal box outputs |
| SC/UPC Pigtail | Replacement fibre termination |
| SC/UPC Adapter | Optical coupling |
| SC/UPC Fast Connector | Field fibre termination |
| FTTH Drop Cable | Subscriber fibre connection |
| Fusion Splice Sleeve | Protects splices |
| Fusion Splicer | Creates permanent fibre joints |
| Fibre Cleaver | Precision fibre preparation |
| Fibre Stripper | Removes coating |
| Connector Cleaner | Cleans SC/UPC ports |
| Optical Power Meter | Measures optical power |
| PON Power Meter | Tests PON signal levels |
| Visual Fault Locator | Fibre tracing |
| OTDR | Diagnoses optical links |
Why Buy from Fiber Optics Kenya?
| Why Choose Fiber Optics Kenya? | Customer Benefit |
|---|---|
| 1x32 Fibre Terminal Boxes | High-density fibre distribution |
| SC/UPC Adapters | Ready connectorized interfaces |
| SC/UPC Pigtails | Professional splice termination |
| 1x32 PLC Splitters | 32-way optical distribution |
| FTTH Drop Cables | Complete subscriber connections |
| Fast Connectors | Convenient field termination |
| Fusion-Splicing Accessories | Professional installation |
| Testing Equipment | Verify optical performance |
| Technical Guidance | Help matching fibre components |
| Bulk Supply | Suitable for ISP deployments |
| Competitive Pricing | Cost-effective fibre rollout |
| Nationwide Delivery | Supply throughout Kenya |
Frequently Asked Questions
What is a 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails?
It is a high-capacity fibre distribution enclosure that can combine a 1x32 PLC splitter, SC/UPC adapter ports and pigtails for up to 32 fibre connections.
What does 1x32 mean?
It means one optical input is split into 32 downstream outputs.
What does SC/UPC mean?
SC/UPC refers to an SC fibre connector with an Ultra Physical Contact polished end face.
What colour are SC/UPC adapters?
They are commonly blue, as shown on current 32-core SC/UPC fibre distribution boxes.
What is a fibre pigtail?
A pigtail is a short optical fibre with a factory-installed connector on one end and bare fibre on the other for fusion splicing.
Why are pigtails used in terminal boxes?
They allow installed fibres to be fusion-spliced internally while providing removable connectorized ports through adapters.
How many adapters can the box support?
A 32-position fibre enclosure can support up to 32 SC-format adapter positions.
How many subscribers can it serve?
Potentially up to 32 downstream connections, depending on the PON design and optical power budget.
Is the splitter single mode?
Yes. 1x32 PLC splitters used in FTTH networks are typically single-mode devices.
What wavelength does a typical 1x32 splitter support?
Professional PLC splitter products commonly operate across 1260–1650 nm.
What is the theoretical splitting loss?
The ideal 1x32 split introduces approximately 15.05 dB of power division loss.
Does it require electricity?
No. PLC splitting and fibre termination are completely passive.
Is it suitable for FTTH?
Yes. 1x32 PLC splitters are specifically suited to high-density FTTH deployments.
Can it be used for GPON?
Yes. PLC splitting is widely used in GPON passive optical distribution.
Can it be used for EPON?
Yes. The same passive splitting principle can be used in compatible EPON architectures.
Does the box support fusion splicing?
Yes. Fibre terminal boxes are designed to accommodate pigtail splicing and fibre termination.
Can SC/APC patch cords be connected to SC/UPC adapters?
No. SC/APC and SC/UPC should not be directly mated because their polished end-face geometries differ.
What is the difference between SC/UPC and SC/APC?
SC/UPC normally uses blue connectors with a straight ultra-polished ferrule, while SC/APC typically uses green connectors with an angled ferrule.
What is the advantage of a loaded terminal box?
It reduces on-site assembly because adapters, pigtails and other fibre components are already installed or supplied.
What is the difference between a 1x16 and 1x32 terminal box?
The 1x32 configuration provides twice as many downstream outputs but introduces approximately 3 dB more theoretical splitter loss.
Can unused ports remain disconnected?
Yes. Unused SC/UPC ports should remain protected with clean dust caps.
Do you supply SC/UPC patch cords?
Yes. Fiber Optics Kenya can supply compatible single-mode SC/UPC patch cords.
Do you supply replacement SC/UPC pigtails?
Yes. Matching single-mode SC/UPC pigtails can be supplied.
Do you supply SC/UPC fast connectors?
Yes. SC/UPC fast connectors are available for field fibre termination.
Do you supply FTTH drop cables?
Yes. Compatible indoor and outdoor FTTH drop cables can be supplied.
Do you supply fusion-splicing tools?
Yes. Fibre cleavers, strippers, fusion splicers and related accessories can be supplied.
Do you supply optical testing equipment?
Yes. Optical power meters, PON meters, VFLs and OTDRs can be supplied.
Do you provide fibre installation and testing?
Yes. Professional fibre installation, fusion splicing, termination and optical testing support is available.
Do you deliver outside Nairobi?
Yes. Fiber Optics Kenya supplies fibre optic products and accessories throughout Kenya.
Contact Fiber Optics Kenya
Fiber Optics Kenya
Lyric House
7th Floor Room S9
Kimathi Street
Nairobi
Phone: +254 704 991 492
Email: info@fibreopticskenya.co.ke
The 1x32 Fibre Terminal Box with SC/UPC Adapters and Pigtails provides an organized, high-capacity solution for splitting, splicing and distributing fibre to up to 32 connections.
Contact Fiber Optics Kenya for 1x32 terminal boxes, SC/UPC adapters and pigtails, FTTH accessories, bulk orders and nationwide delivery across Kenya.
