Fixed ODF Price in Kenya
12 Core ODF with SC/APC Connectors in Kenya
KSh 3,500.00
1 available
Continue shopping12 Core ODF with SC/APC Connectors in Kenya
The 12 Core ODF with SC/APC Connectors is a compact optical distribution frame designed for the termination, fusion splicing, organization, protection and patching of up to 12 optical fibres. It provides a structured connection point between incoming fibre optic cables and network equipment, making fibre management cleaner, safer and easier to maintain.
This ODF configuration uses SC/APC connectors and adapters, normally identified by their green colour. APC stands for Angled Physical Contact, a connector polish designed to reduce reflected optical power. This makes SC/APC particularly suitable for FTTH, GPON, PON and other single-mode fibre networks where low return reflection is important.
At Fiber Optics Kenya, the 12 Core ODF with SC/APC Connectors is suitable for ISPs, telecommunications contractors, network installers, CCTV projects, offices, server rooms, residential fibre infrastructure and enterprise networks. Matching SC/APC pigtails, patch cords, adapters, fibre cables, splice sleeves, fusion-splicing tools and optical testing equipment can also be supplied.
Key Product Specifications
| Specification | Details |
|---|---|
| Product Name | 12 Core ODF with SC/APC Connectors |
| Product Type | Optical Distribution Frame |
| Fibre Capacity | 12 Core |
| Typical Adapter Capacity | 12 SC Simplex |
| Connector Type | SC/APC |
| Typical Connector Colour | Green |
| Polish Type | Angled Physical Contact |
| Fibre Mode | Single Mode |
| Typical Fibre Category | OS2 |
| Typical Fibre Size | 9/125 µm |
| Fusion Splicing | Supported |
| Pigtail Termination | Supported |
| Splice Tray | Integrated / Included depending on model |
| Cable Management | Integrated |
| Fibre Slack Storage | Integrated |
| Typical Housing | Powder-Coated Steel |
| Rack Mounting | Available |
| Typical Rack Format | 19-Inch |
| Typical Height | 1U depending on model |
| Indoor Installation | Yes |
| Electrical Power Required | No |
| Applications | FTTH, GPON, FTTB, LAN, WAN, CCTV, ISP |
| Professional Installation | Available |
| Delivery | Available throughout Kenya |
What Is a 12 Core ODF with SC/APC Connectors?
A 12 Core ODF is a fibre termination enclosure that provides twelve organized optical connection points.
| Component | Function |
|---|---|
| ODF Enclosure | Protects fibre components |
| SC/APC Adapter Panel | Provides 12 fibre interfaces |
| SC/APC Pigtails | Terminates incoming fibres |
| Splice Tray | Stores fusion splices |
| Cable Entry Ports | Receives fibre cable |
| Cable Clamps | Secures incoming cable |
| Fibre Routing Guides | Maintains fibre organization |
| Slack Storage Area | Stores excess fibre |
| Rack Mounting Brackets | Secures ODF in cabinet |
The incoming optical cable is normally fusion-spliced to SC/APC pigtails, which then connect to the green SC/APC adapters installed on the front panel.
What Does ODF Mean?
| Term | Meaning |
|---|---|
| ODF | Optical Distribution Frame |
| 12 Core | Twelve fibre termination positions |
| SC | SC Fibre Connector |
| APC | Angled Physical Contact |
| FTTH | Fibre to the Home |
| GPON | Gigabit Passive Optical Network |
| PON | Passive Optical Network |
| Pigtail | Fibre with a connector on one end |
| Patch Cord | Fibre cable terminated at both ends |
What Does SC/APC Mean?
SC/APC combines the commonly used SC connector format with an angled polished fibre end face.
| SC/APC Feature | Description |
|---|---|
| Connector Type | SC |
| Polish | Angled Physical Contact |
| Typical Colour | Green |
| Fibre Mode | Single Mode |
| Typical Fibre Size | 9/125 µm |
| Back Reflection | Very Low |
| FTTH Compatibility | Excellent |
| GPON Compatibility | Excellent |
| CATV Compatibility | Excellent |
| Connection Style | Push-Pull |
Why SC/APC Connectors Are Used
/product/32/8625032/1.jpg?3626)
The angled fibre end face helps direct reflected light away from the fibre core.
| Advantage | Benefit |
|---|---|
| Low Back Reflection | Better optical signal quality |
| Green Colour Coding | Easy identification |
| Single-Mode Performance | Ideal for long-distance fibre |
| PON Compatibility | Excellent |
| Reliable Patch Connection | Easy network maintenance |
| Widely Used in FTTH | Easy component availability |
How the 12 Core ODF Works
The incoming fibre cable enters the ODF through the rear or side cable entry. Individual fibres are prepared and fusion-spliced to SC/APC pigtails.
| Stage | Function |
|---|---|
| Incoming Fibre Cable | Carries network fibres |
| Cable Entry | Routes cable into ODF |
| Cable Clamp | Secures fibre cable |
| Fibre Separation | Identifies individual cores |
| Fusion Splicing | Joins fibre to pigtail |
| Splice Sleeve | Protects fusion joint |
| Splice Tray | Stores completed splice |
| SC/APC Pigtail | Connects to adapter |
| SC/APC Adapter | Provides front-panel port |
| Patch Cord | Connects network equipment |
12 SC/APC Port Configuration
| Port | Typical Fibre Assignment |
|---|---|
| 1 | Fibre 1 |
| 2 | Fibre 2 |
| 3 | Fibre 3 |
| 4 | Fibre 4 |
| 5 | Fibre 5 |
| 6 | Fibre 6 |
| 7 | Fibre 7 |
| 8 | Fibre 8 |
| 9 | Fibre 9 |
| 10 | Fibre 10 |
| 11 | Fibre 11 |
| 12 | Fibre 12 |
Clear port numbering makes installation, troubleshooting and future network expansion easier.
Typical SC/APC Pigtail Configuration
| Specification | Typical Configuration |
|---|---|
| Quantity | 12 |
| Connector Type | SC/APC |
| Connector Colour | Green |
| Fibre Mode | Single Mode |
| Core / Cladding | 9/125 µm |
| Typical Fibre Category | OS2 |
| Typical Buffer | 900 µm |
| Bare End | Fusion-Splice Ready |
| Typical Length | Around 1–1.5 m depending on product |
SC/APC vs SC/UPC ODF
| Feature | SC/APC | SC/UPC |
|---|---|---|
| Typical Colour | Green | Blue |
| Polish | Angled Physical Contact | Ultra Physical Contact |
| Back Reflection | Lower | Low |
| FTTH / GPON | Very Common | Used where specified |
| CATV Networks | Excellent | Less Preferred |
| Enterprise Networks | Application Dependent | Very Common |
| Direct APC/UPC Mating | No | No |
SC/APC and SC/UPC connectors should not be directly connected because their polished ferrule geometries are different.
12 Core ODF vs 24 Core ODF
| Feature | 12 Core | 24 Core |
|---|---|---|
| Fibre Capacity | 12 | 24 |
| Adapter Capacity | 12 | 24 |
| Small Network | Excellent | Excellent |
| Medium Network | Good | Better |
| Rack Density | Lower | Higher |
| Cable Management | Simpler | More Complex |
| Expansion Capacity | Moderate | Higher |
12 Core ODF vs 48 Core ODF
| Feature | 12 Core | 48 Core |
|---|---|---|
| Maximum Fibre Ports | 12 | 48 |
| Typical Network Size | Small | Medium / Large |
| Server Room Use | Excellent | Excellent |
| CCTV Network | Excellent | Large CCTV Networks |
| ISP POP | Small | Larger |
| Future Expansion | Moderate | High |
ODF vs Fibre Termination Box
| Feature | ODF | Fibre Termination Box |
|---|---|---|
| Typical Mounting | Rack | Wall |
| Patch Cord Access | Excellent | Good |
| Fusion Splicing | Yes | Yes |
| Network Rack Use | Excellent | Limited |
| Outdoor Versions | Less Common | Common |
| Enterprise Use | Excellent | Excellent |
| FTTH Use | Excellent | Excellent |
ODF vs FAT Box
| Feature | ODF | FAT Box |
|---|---|---|
| Main Function | Termination and patching | Subscriber distribution |
| Typical Location | Network / Server Room | FTTH Distribution Network |
| Rack Mounting | Common | Rare |
| PLC Splitters | Possible | Common |
| Patch Cord Management | Excellent | Moderate |
| Subscriber Drop Ports | Less Direct | Excellent |
Fusion Splicing Inside the ODF
| Step | Procedure |
|---|---|
| 1 | Route fibre cable into ODF |
| 2 | Secure cable |
| 3 | Open fibre buffer tube |
| 4 | Identify individual fibres |
| 5 | Strip fibre coating |
| 6 | Clean bare fibre |
| 7 | Precision cleave fibre |
| 8 | Fusion-splice to SC/APC pigtail |
| 9 | Install splice protection sleeve |
| 10 | Store splice inside tray |
| 11 | Connect pigtail to adapter |
| 12 | Label corresponding port |
| 13 | Test optical connection |
Typical 12-Core Fibre Colour Sequence

| Fibre | Typical Colour |
|---|---|
| 1 | Blue |
| 2 | Orange |
| 3 | Green |
| 4 | Brown |
| 5 | Slate |
| 6 | White |
| 7 | Red |
| 8 | Black |
| 9 | Yellow |
| 10 | Violet |
| 11 | Rose |
| 12 | Aqua |
Always verify the actual fibre colour sequence against the cable manufacturer's specifications.
1U Rack-Mount Design
Many 12-core ODFs are designed for compact installation in a standard rack.
| Feature | Typical Specification |
|---|---|
| Rack Standard | 19 Inch |
| Typical Height | 1U |
| Installation | Rack Mounted |
| Housing | Metal |
| Adapter Panel | 12 SC Simplex |
| Cable Entry | Rear / Side |
| Splice Management | Integrated |
| Indoor Use | Yes |
This makes the unit suitable for server rooms, telecommunications cabinets and ISP network racks.
Empty vs Loaded 12 Core ODF
| Feature | Empty ODF | Loaded SC/APC ODF |
|---|---|---|
| Enclosure | Included | Included |
| SC/APC Adapters | Usually Not | Included |
| SC/APC Pigtails | Usually Not | Often Included |
| Splice Tray | Usually Included | Included |
| Ready for Installation | Lower | Higher |
| Configuration Flexibility | Excellent | Moderate |
| Installation Time | Longer | Faster |
A loaded configuration is useful for standardized fibre installations because the adapters and pigtails are already matched.
Key Benefits of 12 Core ODF with SC/APC Connectors
12-Fibre Capacity
Provides organized termination for twelve individual optical fibres.
SC/APC Connectivity
Green SC/APC interfaces are highly suitable for FTTH, GPON and other compatible PON networks.
Low Optical Reflection
The angled connector polish minimizes reflected optical power.
Fusion-Splicing Support
Incoming fibre cores can be permanently spliced to SC/APC pigtails.
Structured Rack Installation
The ODF keeps fibre termination inside an organized telecommunications or network cabinet.
Easy Patching
Front-facing SC/APC interfaces simplify patch-cord installation and maintenance.
Fibre Protection
The metal enclosure protects delicate optical fibres, pigtails and fusion splices.
Passive Operation
No electrical power is required.
Watch 12 Core ODF with SC/APC Connectors
Watch on YouTube: https://youtu.be/TFkKg-zzED0
The 12 Core ODF with SC/APC Connectors provides a structured way to terminate twelve single-mode optical fibres inside a network rack. The incoming fibres can be fusion-spliced to SC/APC pigtails and connected to green SC/APC adapters on the front panel, creating accessible fibre ports that can be patched to switches, OLT equipment, media converters or other optical devices.
SC/APC connectivity makes the ODF particularly useful in FTTH and GPON environments because the angled physical-contact interface is designed to reduce reflected optical power. Keeping the same APC connector polish across pigtails, adapters and patch cords also helps technicians maintain consistent and properly matched fibre connections throughout the network.
For network installers and ISPs, an ODF helps simplify fibre identification, future maintenance and expansion by separating individual fibres into clearly labelled ports. Fiber Optics Kenya can supply the 12 Core ODF with SC/APC Connectors together with SC/APC pigtails, patch cords, adapters, fibre cables, fusion-splice sleeves, fibre cleaners, optical power meters, VFLs and OTDR equipment for complete fibre termination installations.
Applications of 12 Core ODF with SC/APC Connectors

1. FTTH Networks
Provides organized fibre termination at network and aggregation points.
2. GPON Networks
Suitable for terminating compatible SC/APC fibre links between PON infrastructure components.
3. ISP Network Racks
Terminates incoming distribution or backbone fibres inside network cabinets.
4. Server Rooms
Provides structured fibre patching to switches and optical equipment.
5. FTTB Networks
Terminates building backbone fibres inside telecommunications rooms.
6. CCTV Fibre Networks
Provides centralized termination for multiple fibre CCTV links.
7. Campus Networks
Organizes building-to-building optical fibre connections.
8. Enterprise LAN Networks
Provides fibre uplink termination for switches and backbone networks.
9. Telecommunications Networks
Creates organized fibre cross-connection points.
10. Industrial Fibre Networks
Provides protected termination for optical communication infrastructure.
Typical Network Architecture
| Network Stage | Component |
|---|---|
| Incoming Fibre | 12 Core Fibre Cable |
| Termination Point | 12 Core ODF |
| Splicing | Fibre to SC/APC Pigtails |
| Front Interfaces | 12 × SC/APC |
| Patch Cord | SC/APC or Hybrid Fibre Patch Cord |
| Active Equipment | OLT / Switch / Media Converter |
| Distribution | LAN / WAN / FTTH Network |
Installation Considerations
| Installation Factor | Recommendation |
|---|---|
| Rack Compatibility | Confirm required rack size |
| Connector Type | Maintain SC/APC compatibility |
| Cable Entry | Secure incoming cable properly |
| Strength Member | Anchor correctly |
| Fusion Splicing | Use professional splicing procedures |
| Splice Protection | Use heat-shrink sleeves |
| Fibre Bend Radius | Avoid excessive bending |
| Port Labelling | Clearly number ports 1–12 |
| Connector Cleaning | Clean before every connection |
| Unused Ports | Keep dust caps installed |
| Testing | Test every terminated fibre |
| Documentation | Record fibre-to-port assignment |
Recommended Accessories
| Accessory | Purpose |
|---|---|
| SC/APC Adapter | Fibre coupling |
| SC/APC Pigtail | Fusion-splice termination |
| SC/APC Patch Cord | Optical interconnection |
| SC/APC to LC/APC Patch Cord | Connects compatible LC/APC equipment |
| 12 Core Fibre Cable | Backbone or distribution fibre |
| Fusion Splice Sleeve | Protects fibre joint |
| Splice Tray | Organizes fusion joints |
| Cable Gland | Secures incoming fibre |
| Fibre Labels | Port identification |
| Fusion Splicer | Permanent fibre joining |
| Fibre Cleaver | Precision fibre preparation |
| Fibre Stripper | Removes fibre coating |
| SC/APC Cleaner | Cleans connector ferrules |
| Optical Power Meter | Measures fibre signal |
| Visual Fault Locator | Tests continuity |
| PON Power Meter | Tests GPON signal levels |
| OTDR | Diagnoses fibre links |
Why Buy 12 Core ODF with SC/APC Connectors from Fiber Optics Kenya?

| Why Choose Fiber Optics Kenya? | Customer Benefit |
|---|---|
| 12 Core ODFs | Organized fibre termination |
| SC/APC Adapters | Low-reflection fibre connectivity |
| SC/APC Pigtails | Professional fibre splicing |
| SC/APC Patch Cords | Complete optical patching |
| Hybrid Patch Cords | Connect different equipment interfaces |
| Fibre Optic Cables | Complete network infrastructure |
| Fusion-Splicing Accessories | Professional installation |
| Fibre Cleaning Tools | Reliable connector performance |
| Testing Equipment | Verify optical signal quality |
| Technical Guidance | Correct product matching |
| Bulk Supply | Suitable for ISPs and contractors |
| Nationwide Delivery | Supply throughout Kenya |
Frequently Asked Questions
What is a 12 Core ODF with SC/APC Connectors?
It is a fibre termination and patching enclosure designed to manage up to twelve optical fibres using SC/APC interfaces.
What does ODF mean?
ODF means Optical Distribution Frame.
How many fibres can it terminate?
It can typically terminate 12 individual optical fibres.
How many SC/APC ports does it have?
A standard configuration provides 12 SC simplex adapter positions.
What colour are SC/APC connectors?
SC/APC connectors and adapters are normally green.
What does APC mean?
APC means Angled Physical Contact.
Is SC/APC single mode?
SC/APC connectors are predominantly used with single-mode fibre, including OS2 fibre systems.
Is it suitable for FTTH?
Yes. SC/APC is widely used in FTTH networks.
Can it be used for GPON?
Yes. SC/APC connectivity is particularly suitable for compatible GPON infrastructure.
Does it support fusion splicing?
Yes. Incoming fibres can be fusion-spliced to SC/APC pigtails.
Does it include SC/APC adapters?
A loaded SC/APC version normally includes the adapters. Empty versions may require adapters to be purchased separately.
Does it include pigtails?
Loaded models often include matching SC/APC pigtails, while empty ODFs may not.
Is it rack mounted?
Many 12-core ODFs are designed for standard telecommunications and network racks.
Is it normally 1U?
Many 12-port rack-mount models use a compact 1U format, although the exact enclosure should be confirmed.
Can SC/UPC patch cords connect directly to SC/APC adapters?
No. SC/APC and SC/UPC connectors should not be directly mated.
What is the difference between SC/APC and SC/UPC?
SC/APC is normally green and uses an angled ferrule end face, while SC/UPC is normally blue and uses an ultra-polished end face.
Can it connect to LC equipment?
Yes, provided an appropriate SC/APC-to-LC/APC patch cord is used and the equipment uses compatible APC interfaces.
Can it terminate multimode fibre?
The enclosure may physically accommodate multimode components, but SC/APC configurations are primarily used with single-mode networks.
Can it be used for CCTV fibre?
Yes. It can terminate multiple fibre links used for CCTV transmission.
Can it be installed in a server room?
Yes. Rack-mounted ODFs are ideal for server and telecommunications rooms.
Can it be used in an ISP POP?
Yes. It provides organized termination for ISP backbone and distribution fibres.
Can it be installed outdoors?
Rack-mounted ODFs are generally intended for protected indoor environments.
Does it require electricity?
No. The ODF is a completely passive fibre-management device.
What is the difference between a 12 Core and 24 Core ODF?
A 24-core ODF provides twice the nominal fibre capacity.
What is the difference between an ODF and FAT box?
An ODF primarily handles fibre termination and patching in racks, while a FAT box generally distributes fibres to subscribers in an FTTH access network.
Can unused ports remain spare?
Yes. Unused adapters should remain protected with dust caps.
Can fibre slack be stored inside?
Yes. ODFs provide internal space for controlled fibre slack and pigtail management.
Do you supply SC/APC adapters?
Yes. Fiber Optics Kenya can supply compatible SC/APC adapters.
Do you supply SC/APC pigtails?
Yes. Matching single-mode SC/APC pigtails can be supplied.
Do you supply SC/APC patch cords?
Yes. SC/APC patch cords and compatible hybrid patch cords can be supplied.
Do you supply fibre optic cables?
Yes. Indoor, outdoor, armoured, ADSS and other fibre optic cables can be supplied.
Do you supply fusion-splicing tools?
Yes. Fusion splicers, cleavers, fibre strippers, splice sleeves and related installation tools can be supplied.
Do you supply fibre testing equipment?
Yes. Optical power meters, PON power meters, VFLs and OTDRs can be supplied.
Do you provide fibre installation and testing?
Yes. Professional fibre termination, fusion splicing, rack installation and optical testing support is available.
Do you deliver outside Nairobi?
Yes. Fiber Optics Kenya supplies fibre optic products and accessories throughout Kenya.
Contact Fiber Optics Kenya
Fiber Optics Kenya
Lyric House
7th Floor Room S9
Kimathi Street
Nairobi
Phone: +254 704 991 492
Email: info@fibreopticskenya.co.ke
The 12 Core ODF with SC/APC Connectors provides a compact and professional solution for terminating, fusion-splicing and patching up to twelve single-mode optical fibres in FTTH, GPON, ISP, CCTV and enterprise networks.
Contact Fiber Optics Kenya for 12 Core SC/APC ODFs, adapters, pigtails, patch cords, fibre cables, fusion-splicing accessories, bulk orders and nationwide delivery across Kenya.