12 Core ODF with SC/APC Connectors in Kenya

Fixed ODF Price in Kenya

12 Core ODF with SC/APC Connectors in Kenya

KSh 3,500.00

1 available

Continue shopping

12 Core ODF with SC/APC Connectors in Kenya

Fiber Optic 12 Core ODF with SC/APC connector

The 12 Core ODF with SC/APC Connectors is a compact optical distribution frame designed for the termination, fusion splicing, organization, protection and patching of up to 12 optical fibres. It provides a structured connection point between incoming fibre optic cables and network equipment, making fibre management cleaner, safer and easier to maintain.

This ODF configuration uses SC/APC connectors and adapters, normally identified by their green colour. APC stands for Angled Physical Contact, a connector polish designed to reduce reflected optical power. This makes SC/APC particularly suitable for FTTH, GPON, PON and other single-mode fibre networks where low return reflection is important.

At Fiber Optics Kenya, the 12 Core ODF with SC/APC Connectors is suitable for ISPs, telecommunications contractors, network installers, CCTV projects, offices, server rooms, residential fibre infrastructure and enterprise networks. Matching SC/APC pigtails, patch cords, adapters, fibre cables, splice sleeves, fusion-splicing tools and optical testing equipment can also be supplied.

Key Product Specifications

SpecificationDetails
Product Name12 Core ODF with SC/APC Connectors
Product TypeOptical Distribution Frame
Fibre Capacity12 Core
Typical Adapter Capacity12 SC Simplex
Connector TypeSC/APC
Typical Connector ColourGreen
Polish TypeAngled Physical Contact
Fibre ModeSingle Mode
Typical Fibre CategoryOS2
Typical Fibre Size9/125 µm
Fusion SplicingSupported
Pigtail TerminationSupported
Splice TrayIntegrated / Included depending on model
Cable ManagementIntegrated
Fibre Slack StorageIntegrated
Typical HousingPowder-Coated Steel
Rack MountingAvailable
Typical Rack Format19-Inch
Typical Height1U depending on model
Indoor InstallationYes
Electrical Power RequiredNo
ApplicationsFTTH, GPON, FTTB, LAN, WAN, CCTV, ISP
Professional InstallationAvailable
DeliveryAvailable throughout Kenya

What Is a 12 Core ODF with SC/APC Connectors?

A 12 Core ODF is a fibre termination enclosure that provides twelve organized optical connection points.

ComponentFunction
ODF EnclosureProtects fibre components
SC/APC Adapter PanelProvides 12 fibre interfaces
SC/APC PigtailsTerminates incoming fibres
Splice TrayStores fusion splices
Cable Entry PortsReceives fibre cable
Cable ClampsSecures incoming cable
Fibre Routing GuidesMaintains fibre organization
Slack Storage AreaStores excess fibre
Rack Mounting BracketsSecures ODF in cabinet

The incoming optical cable is normally fusion-spliced to SC/APC pigtails, which then connect to the green SC/APC adapters installed on the front panel.

What Does ODF Mean?

TermMeaning
ODFOptical Distribution Frame
12 CoreTwelve fibre termination positions
SCSC Fibre Connector
APCAngled Physical Contact
FTTHFibre to the Home
GPONGigabit Passive Optical Network
PONPassive Optical Network
PigtailFibre with a connector on one end
Patch CordFibre cable terminated at both ends

What Does SC/APC Mean?

SC/APC combines the commonly used SC connector format with an angled polished fibre end face.

SC/APC FeatureDescription
Connector TypeSC
PolishAngled Physical Contact
Typical ColourGreen
Fibre ModeSingle Mode
Typical Fibre Size9/125 µm
Back ReflectionVery Low
FTTH CompatibilityExcellent
GPON CompatibilityExcellent
CATV CompatibilityExcellent
Connection StylePush-Pull

Why SC/APC Connectors Are Used

Fiber Optic 12 Core ODF with SC/APC connector @ Best Price

The angled fibre end face helps direct reflected light away from the fibre core.

AdvantageBenefit
Low Back ReflectionBetter optical signal quality
Green Colour CodingEasy identification
Single-Mode PerformanceIdeal for long-distance fibre
PON CompatibilityExcellent
Reliable Patch ConnectionEasy network maintenance
Widely Used in FTTHEasy component availability

How the 12 Core ODF Works

The incoming fibre cable enters the ODF through the rear or side cable entry. Individual fibres are prepared and fusion-spliced to SC/APC pigtails.

StageFunction
Incoming Fibre CableCarries network fibres
Cable EntryRoutes cable into ODF
Cable ClampSecures fibre cable
Fibre SeparationIdentifies individual cores
Fusion SplicingJoins fibre to pigtail
Splice SleeveProtects fusion joint
Splice TrayStores completed splice
SC/APC PigtailConnects to adapter
SC/APC AdapterProvides front-panel port
Patch CordConnects network equipment

12 SC/APC Port Configuration

PortTypical Fibre Assignment
1Fibre 1
2Fibre 2
3Fibre 3
4Fibre 4
5Fibre 5
6Fibre 6
7Fibre 7
8Fibre 8
9Fibre 9
10Fibre 10
11Fibre 11
12Fibre 12

Clear port numbering makes installation, troubleshooting and future network expansion easier.

Typical SC/APC Pigtail Configuration

SpecificationTypical Configuration
Quantity12
Connector TypeSC/APC
Connector ColourGreen
Fibre ModeSingle Mode
Core / Cladding9/125 µm
Typical Fibre CategoryOS2
Typical Buffer900 µm
Bare EndFusion-Splice Ready
Typical LengthAround 1–1.5 m depending on product

SC/APC vs SC/UPC ODF

FeatureSC/APCSC/UPC
Typical ColourGreenBlue
PolishAngled Physical ContactUltra Physical Contact
Back ReflectionLowerLow
FTTH / GPONVery CommonUsed where specified
CATV NetworksExcellentLess Preferred
Enterprise NetworksApplication DependentVery Common
Direct APC/UPC MatingNoNo

SC/APC and SC/UPC connectors should not be directly connected because their polished ferrule geometries are different.

12 Core ODF vs 24 Core ODF

Feature12 Core24 Core
Fibre Capacity1224
Adapter Capacity1224
Small NetworkExcellentExcellent
Medium NetworkGoodBetter
Rack DensityLowerHigher
Cable ManagementSimplerMore Complex
Expansion CapacityModerateHigher

12 Core ODF vs 48 Core ODF

Feature12 Core48 Core
Maximum Fibre Ports1248
Typical Network SizeSmallMedium / Large
Server Room UseExcellentExcellent
CCTV NetworkExcellentLarge CCTV Networks
ISP POPSmallLarger
Future ExpansionModerateHigh

ODF vs Fibre Termination Box

FeatureODFFibre Termination Box
Typical MountingRackWall
Patch Cord AccessExcellentGood
Fusion SplicingYesYes
Network Rack UseExcellentLimited
Outdoor VersionsLess CommonCommon
Enterprise UseExcellentExcellent
FTTH UseExcellentExcellent

ODF vs FAT Box

FeatureODFFAT Box
Main FunctionTermination and patchingSubscriber distribution
Typical LocationNetwork / Server RoomFTTH Distribution Network
Rack MountingCommonRare
PLC SplittersPossibleCommon
Patch Cord ManagementExcellentModerate
Subscriber Drop PortsLess DirectExcellent

Fusion Splicing Inside the ODF

StepProcedure
1Route fibre cable into ODF
2Secure cable
3Open fibre buffer tube
4Identify individual fibres
5Strip fibre coating
6Clean bare fibre
7Precision cleave fibre
8Fusion-splice to SC/APC pigtail
9Install splice protection sleeve
10Store splice inside tray
11Connect pigtail to adapter
12Label corresponding port
13Test optical connection

Typical 12-Core Fibre Colour Sequence

ODF Optical Distribution Frame 12 Core SC/UPC Coupler With Pigtail Optical  Fiber Splicing Tray - Shenzhen Bestwe Electronics Technology Co. Ltd.
FibreTypical Colour
1Blue
2Orange
3Green
4Brown
5Slate
6White
7Red
8Black
9Yellow
10Violet
11Rose
12Aqua

Always verify the actual fibre colour sequence against the cable manufacturer's specifications.

1U Rack-Mount Design

Many 12-core ODFs are designed for compact installation in a standard rack.

FeatureTypical Specification
Rack Standard19 Inch
Typical Height1U
InstallationRack Mounted
HousingMetal
Adapter Panel12 SC Simplex
Cable EntryRear / Side
Splice ManagementIntegrated
Indoor UseYes

This makes the unit suitable for server rooms, telecommunications cabinets and ISP network racks.

Empty vs Loaded 12 Core ODF

FeatureEmpty ODFLoaded SC/APC ODF
EnclosureIncludedIncluded
SC/APC AdaptersUsually NotIncluded
SC/APC PigtailsUsually NotOften Included
Splice TrayUsually IncludedIncluded
Ready for InstallationLowerHigher
Configuration FlexibilityExcellentModerate
Installation TimeLongerFaster

A loaded configuration is useful for standardized fibre installations because the adapters and pigtails are already matched.

Key Benefits of 12 Core ODF with SC/APC Connectors

12-Fibre Capacity

Provides organized termination for twelve individual optical fibres.

SC/APC Connectivity

Green SC/APC interfaces are highly suitable for FTTH, GPON and other compatible PON networks.

Low Optical Reflection

The angled connector polish minimizes reflected optical power.

Fusion-Splicing Support

Incoming fibre cores can be permanently spliced to SC/APC pigtails.

Structured Rack Installation

The ODF keeps fibre termination inside an organized telecommunications or network cabinet.

Easy Patching

Front-facing SC/APC interfaces simplify patch-cord installation and maintenance.

Fibre Protection

The metal enclosure protects delicate optical fibres, pigtails and fusion splices.

Passive Operation

No electrical power is required.

Watch 12 Core ODF with SC/APC Connectors

Watch on YouTube: https://youtu.be/TFkKg-zzED0

The 12 Core ODF with SC/APC Connectors provides a structured way to terminate twelve single-mode optical fibres inside a network rack. The incoming fibres can be fusion-spliced to SC/APC pigtails and connected to green SC/APC adapters on the front panel, creating accessible fibre ports that can be patched to switches, OLT equipment, media converters or other optical devices.

SC/APC connectivity makes the ODF particularly useful in FTTH and GPON environments because the angled physical-contact interface is designed to reduce reflected optical power. Keeping the same APC connector polish across pigtails, adapters and patch cords also helps technicians maintain consistent and properly matched fibre connections throughout the network.

For network installers and ISPs, an ODF helps simplify fibre identification, future maintenance and expansion by separating individual fibres into clearly labelled ports. Fiber Optics Kenya can supply the 12 Core ODF with SC/APC Connectors together with SC/APC pigtails, patch cords, adapters, fibre cables, fusion-splice sleeves, fibre cleaners, optical power meters, VFLs and OTDR equipment for complete fibre termination installations.

Applications of 12 Core ODF with SC/APC Connectors

Buy Fiber Optic 12 Core ODF with SC/APC connector - CTC Kenya

1. FTTH Networks

Provides organized fibre termination at network and aggregation points.

2. GPON Networks

Suitable for terminating compatible SC/APC fibre links between PON infrastructure components.

3. ISP Network Racks

Terminates incoming distribution or backbone fibres inside network cabinets.

4. Server Rooms

Provides structured fibre patching to switches and optical equipment.

5. FTTB Networks

Terminates building backbone fibres inside telecommunications rooms.

6. CCTV Fibre Networks

Provides centralized termination for multiple fibre CCTV links.

7. Campus Networks

Organizes building-to-building optical fibre connections.

8. Enterprise LAN Networks

Provides fibre uplink termination for switches and backbone networks.

9. Telecommunications Networks

Creates organized fibre cross-connection points.

10. Industrial Fibre Networks

Provides protected termination for optical communication infrastructure.

Typical Network Architecture

Network StageComponent
Incoming Fibre12 Core Fibre Cable
Termination Point12 Core ODF
SplicingFibre to SC/APC Pigtails
Front Interfaces12 × SC/APC
Patch CordSC/APC or Hybrid Fibre Patch Cord
Active EquipmentOLT / Switch / Media Converter
DistributionLAN / WAN / FTTH Network

Installation Considerations

Installation FactorRecommendation
Rack CompatibilityConfirm required rack size
Connector TypeMaintain SC/APC compatibility
Cable EntrySecure incoming cable properly
Strength MemberAnchor correctly
Fusion SplicingUse professional splicing procedures
Splice ProtectionUse heat-shrink sleeves
Fibre Bend RadiusAvoid excessive bending
Port LabellingClearly number ports 1–12
Connector CleaningClean before every connection
Unused PortsKeep dust caps installed
TestingTest every terminated fibre
DocumentationRecord fibre-to-port assignment

Recommended Accessories

AccessoryPurpose
SC/APC AdapterFibre coupling
SC/APC PigtailFusion-splice termination
SC/APC Patch CordOptical interconnection
SC/APC to LC/APC Patch CordConnects compatible LC/APC equipment
12 Core Fibre CableBackbone or distribution fibre
Fusion Splice SleeveProtects fibre joint
Splice TrayOrganizes fusion joints
Cable GlandSecures incoming fibre
Fibre LabelsPort identification
Fusion SplicerPermanent fibre joining
Fibre CleaverPrecision fibre preparation
Fibre StripperRemoves fibre coating
SC/APC CleanerCleans connector ferrules
Optical Power MeterMeasures fibre signal
Visual Fault LocatorTests continuity
PON Power MeterTests GPON signal levels
OTDRDiagnoses fibre links

Why Buy 12 Core ODF with SC/APC Connectors from Fiber Optics Kenya?

ODF 12 Core SC Simplex Loaded - True Tech
Why Choose Fiber Optics Kenya?Customer Benefit
12 Core ODFsOrganized fibre termination
SC/APC AdaptersLow-reflection fibre connectivity
SC/APC PigtailsProfessional fibre splicing
SC/APC Patch CordsComplete optical patching
Hybrid Patch CordsConnect different equipment interfaces
Fibre Optic CablesComplete network infrastructure
Fusion-Splicing AccessoriesProfessional installation
Fibre Cleaning ToolsReliable connector performance
Testing EquipmentVerify optical signal quality
Technical GuidanceCorrect product matching
Bulk SupplySuitable for ISPs and contractors
Nationwide DeliverySupply throughout Kenya

Frequently Asked Questions

What is a 12 Core ODF with SC/APC Connectors?

It is a fibre termination and patching enclosure designed to manage up to twelve optical fibres using SC/APC interfaces.

What does ODF mean?

ODF means Optical Distribution Frame.

How many fibres can it terminate?

It can typically terminate 12 individual optical fibres.

How many SC/APC ports does it have?

A standard configuration provides 12 SC simplex adapter positions.

What colour are SC/APC connectors?

SC/APC connectors and adapters are normally green.

What does APC mean?

APC means Angled Physical Contact.

Is SC/APC single mode?

SC/APC connectors are predominantly used with single-mode fibre, including OS2 fibre systems.

Is it suitable for FTTH?

Yes. SC/APC is widely used in FTTH networks.

Can it be used for GPON?

Yes. SC/APC connectivity is particularly suitable for compatible GPON infrastructure.

Does it support fusion splicing?

Yes. Incoming fibres can be fusion-spliced to SC/APC pigtails.

Does it include SC/APC adapters?

A loaded SC/APC version normally includes the adapters. Empty versions may require adapters to be purchased separately.

Does it include pigtails?

Loaded models often include matching SC/APC pigtails, while empty ODFs may not.

Is it rack mounted?

Many 12-core ODFs are designed for standard telecommunications and network racks.

Is it normally 1U?

Many 12-port rack-mount models use a compact 1U format, although the exact enclosure should be confirmed.

Can SC/UPC patch cords connect directly to SC/APC adapters?

No. SC/APC and SC/UPC connectors should not be directly mated.

What is the difference between SC/APC and SC/UPC?

SC/APC is normally green and uses an angled ferrule end face, while SC/UPC is normally blue and uses an ultra-polished end face.

Can it connect to LC equipment?

Yes, provided an appropriate SC/APC-to-LC/APC patch cord is used and the equipment uses compatible APC interfaces.

Can it terminate multimode fibre?

The enclosure may physically accommodate multimode components, but SC/APC configurations are primarily used with single-mode networks.

Can it be used for CCTV fibre?

Yes. It can terminate multiple fibre links used for CCTV transmission.

Can it be installed in a server room?

Yes. Rack-mounted ODFs are ideal for server and telecommunications rooms.

Can it be used in an ISP POP?

Yes. It provides organized termination for ISP backbone and distribution fibres.

Can it be installed outdoors?

Rack-mounted ODFs are generally intended for protected indoor environments.

Does it require electricity?

No. The ODF is a completely passive fibre-management device.

What is the difference between a 12 Core and 24 Core ODF?

A 24-core ODF provides twice the nominal fibre capacity.

What is the difference between an ODF and FAT box?

An ODF primarily handles fibre termination and patching in racks, while a FAT box generally distributes fibres to subscribers in an FTTH access network.

Can unused ports remain spare?

Yes. Unused adapters should remain protected with dust caps.

Can fibre slack be stored inside?

Yes. ODFs provide internal space for controlled fibre slack and pigtail management.

Do you supply SC/APC adapters?

Yes. Fiber Optics Kenya can supply compatible SC/APC adapters.

Do you supply SC/APC pigtails?

Yes. Matching single-mode SC/APC pigtails can be supplied.

Do you supply SC/APC patch cords?

Yes. SC/APC patch cords and compatible hybrid patch cords can be supplied.

Do you supply fibre optic cables?

Yes. Indoor, outdoor, armoured, ADSS and other fibre optic cables can be supplied.

Do you supply fusion-splicing tools?

Yes. Fusion splicers, cleavers, fibre strippers, splice sleeves and related installation tools can be supplied.

Do you supply fibre testing equipment?

Yes. Optical power meters, PON power meters, VFLs and OTDRs can be supplied.

Do you provide fibre installation and testing?

Yes. Professional fibre termination, fusion splicing, rack installation and optical testing support is available.

Do you deliver outside Nairobi?

Yes. Fiber Optics Kenya supplies fibre optic products and accessories throughout Kenya.

Contact Fiber Optics Kenya

Fiber Optics Kenya
Lyric House
7th Floor Room S9
Kimathi Street
Nairobi

Phone: +254 704 991 492
Email: info@fibreopticskenya.co.ke

The 12 Core ODF with SC/APC Connectors provides a compact and professional solution for terminating, fusion-splicing and patching up to twelve single-mode optical fibres in FTTH, GPON, ISP, CCTV and enterprise networks.

Contact Fiber Optics Kenya for 12 Core SC/APC ODFs, adapters, pigtails, patch cords, fibre cables, fusion-splicing accessories, bulk orders and nationwide delivery across Kenya.